Review Date Reviewer's Name Type of Review Description Status Comments
11/22/2023 Residential Building NOT REQUIRED
12/04/2023 Site Engineering NOT REQUIRED
12/04/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/27/2023 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-1123-09338
8736 E. Patterson Dr. - R-1
CE-VIO1023-06259 Gacebo, Wood Shed, Metal Shed (1st Review)

TRANSMITTAL DATE: November 27, 2023

Provided a detailed comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9.

1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example, to include but not limited to:
a. The plot plan shall show the entire parcel with property line dimensions shown.
b. The plot plan shall be drawn at an engineering scale, i.e., 1” = 10’, 1” = 20’.
c. Provide the owners name on the plot plan.
d. Provide a lot coverage calculation on the plot plan.
e. Show all utility lines on the plot plan.
f. Provide the legal description, “EASTERN HILLS LOT 3 BLK 4” on the plot plan.
g. Indicate the zoning of this parcel and all adjacent properties.

2. Per Unified Development Code (UDC) Table 6.3-2.A the perimeter yard setback to any interior property line is 6’-0” or 2/3 the height of the exterior wall. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Where the wall meets the eave of the roof. Based on the 10’ height provided for the “Tool Storage” the required perimeter yard setback is 6’-8” proposed setback is 2’-0”. Based on the 7’ height provided for the “Metal Storage” the required perimeter yard setback is 6’-0” proposed setback is 2’-0”. At a minimum a neighbors setback waiver is required for the reduced setbacks. To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s):
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________
If you are not able to secure the setback waiver a Design Development Options (DDO) will need to be submitted and approved. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
11/09/2023 PDSD Application Completeness Express REVIEW COMPLETED