Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-1123-09292
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/08/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/08/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-1123-09292 (2045 E ADAMS ST TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). Wrong permit type. This scope of work should have been filed as a Residential alterations permit. General: 1. Clarify the “Chanel through the brick/adobe walls”. Is this a bore hole through the brick or an actual channel along the length of the brick wall? Any modifications to the brick wall shall not compromise the structural integrity of the wall, R102.7.1, R301.1. 2. Clarify if “Part 1” and “Part 2” are apart of the same permit. Floor Plan: 3. Provide an updated floor plan that clearly identifies the scope and location of all work being performed, R106.1.1. The provided site plan is cut off. ELECTRICAL PLANS: 1. Provide a panel schedule showing panel size, circuit numbers, ampacity, wire size and general description, E3404.13 & E3706.2. Provide a panel schedule showing wire size of each circuit or notate the wire size for each protection rating, E3702.2. 2. Designate the circuit number at the location of each light fixture, receptacle, appliance, and equipment disconnect switch, E3404.12. 3. Show the location of each outlet on the Electrical Plan, E3404.12. 4. Show access and working space around all electrical equipment for safe operation and maintenance of equipment, E3405.1. 5. Show all receptacle outlets located outdoors, at bathrooms, kitchen countertops, unfinished basements, garages or carports at grade level and within 6’ of a wet bar or sink with ground fault circuit interrupting protection, E3902. 6. Show weatherproof covers at electrical boxes in damp or wet locations, E3905.11. 7. Protection of all interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. 8. Protect extended branch circuits with combination type arc-fault circuit interrupters, or an AFCI type receptacle at the first outlet on the branch circuit, E3902.17. 9. Provide notation requiring tamper resistant receptacles for 125 volt, 15A and 20A receptacles, R4002.14. 10. Conductors in attics shall comply with E3802.2. Make a notation on the plans. 11. Junction boxes in the attic shall comply with E3905, E3905.10. Make a notation on the plans. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 11/06/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |