Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1123-09275
Parcel: 133430420

Address:
742 N COLETTE PL

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-1123-09275
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/12/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/29/2024 Residential Building REQUIRES RESUBMIT Provide a complete plan set showing 2018 IRC compliance

Roof Framing Plan: Locate and size beams, joist, and fasteners for supporting live and dead structural loads, R804 or provide an engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1.

Cross-Section Detail: Show proposed material types and sizes with fastening devices including all connection points from a foundation structure to the dwelling roof, R106.1.

A special inspection request is required with the permit application for field welding, R109.2. Show manufactured assemblies without field welding or submit a privately acquired certified inspector request form for approval.
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Inspections
06/12/2024 Site Zoning REQUIRES RESUBMIT FROM: Nicholas Martell
PDSD Zoning Review Section
PROJECT: TC-RES-1123-09275
742 N COLETTE PL
Zoning RX-1 Metal shade structure (2nd Review)

TRANSMITTAL DATE:‎
June 12, 2024

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1.The following comment was not fully addressed:
“COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf This shall in include: a. Setback dimension b. Zoning of adjacent parcels c. All Utility lines d. Property line distances”
Please add the setback dimensions from the proposed covered parking area to the property line. Provide a distance from both corners of the structure and an average setback dimension. Without an accurate setback measurement, the Design Development Option process (DDO) cannot be started.

2.COMMENT: Based on an estimated wall height of 15’3” (the midpoint of the entire detached structure), a board of adjust variance is required. Per UDC section 6.6.3.D “Accessory structures , except for accessory dwelling units , shall not exceed 12 feet in height, unless attached to a principal structure” To apply for the variance, please contact Mark.Castro@tucsonaz.gov. More information regarding the variance process can be found here: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-2

3.COMMENT: Per UDC Article 6.6.3.E “The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure. Accessory structures less than 200 square feet gfa and accessory dwelling units are exempt from this requirement” Based on the addition of 660 square feet to the existing accessory structure, the total square footage of accessory structures on site is 2,976 square feet. Based on the 4,979 square foot primary structure, the total gross floor area of the accessory structures exceeds the 50% GFA rule. A board of adjustment variance can be requested on the same variance application mentioned above.
If the applicant chooses not to apply for the variance, the accessory structure can be attached to the primary structure with a 4’ wide roof attachment that can handle a 20 LB live load.

For any questions regarding this submittal, please contact me at Nicholas.martell@tucsonaz.gov
05/29/2024 PDSD Application Completeness Express REVIEW COMPLETED