Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1123-09275
Parcel: 133430420

Address:
742 N COLETTE PL

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.3

Permit Number - TC-RES-1123-09275
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/31/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/02/2024 Residential Building REQUIRES RESUBMIT TC-RES-1123-09275 3rd
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections.

Provide a response letter on separate file with a complete construction plan set for both the carport and covered attachment between buildings.

Field welding requires a special inspection request form for review with the permit plans, R109.2. Provide a certified inspector seal on the form found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Inspections

SITE PLAN:

Show the location of utility lines from property line to building(s) requiring alterations, R106.1.1.

STRUCTURAL PLANS:

1. Provide a complete plan set showing materials and fastener sizes with 2018 IRC prescriptive compliance or provide an Arizona professional stamped plan set showing performance compliance with wind loading conditions, R301.1.

SECTIONS - DETAILS:

1. Provide a structure section showing existing and proposed features including a foundation, framing, sills, anchoring, sheathing and insulation, R106.1.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
07/23/2024 Site Zoning REQUIRES RESUBMIT FROM: Loran Shamis
PDSD Zoning Review Section
PROJECT: TC-RES-1123-09275
742 N COLETTE PL
Zoning RX-1 Metal shade structure (3rd Review)
TRANSMITTAL DATE:‎ June 23, 2024

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.
1. COMMENT: the proposed addition does not appear to be meeting the minimum required setbacks, therefore, approval through a Design Development Option (DDO) would be required to permit this proposal. Per UDC Table 6.3-1.A the minimum required setback for a residential use in a residential zone is 20’ measured from the property line to the exterior wall of the structure and the proposed setbacks are 12’10” and 6’4”. Until the DDO has been approved, Zoning cannot approve the proposal.
2. COMMENT: Please include the elevation drawing in the same document as the site plan. The elevation drawing was included on the previous plan set submittal but should be included on all submittals as well as should be demonstrating the attachment to be consistent with the site plan.
3. COMMENT: Per the Zoning Administrators determination dated December 1, 2008, to consider an accessory structure attached "A structural element that is a minimum five (5) foot wide and supports a minimum twenty (20) pound live load." Please modify your breezeway design to meet the minimum width requirement and include a statement that the attachment can support a 20 lb live load.

For any questions regarding this submittal, please contact me at Loran.Shamis@tucsonaz.gov
07/31/2024 Zoning Modifications - DDO REQUIRES RESUBMIT FROM: GEORGIA PENNINGTON,PLANNER
DATE: 7/31/24

1. Address Site Zoning comments prior to DDO processing.

If you have any questions, please contact me at georgia.pennington@hotmail.com
06/26/2024 PDSD Application Completeness Express REVIEW COMPLETED