Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.2
Permit Number - TC-RES-1123-09270
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/08/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/08/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-1123-09270 (2841 E LORETTA DR Unit:UNIT 1-2 TUCSON, AZ 85716) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. The 1” pipe is undersized for the given length and total demand, see Table G2413.4(1). 2. The ¾” segment is undersized for the given length and combined demand of the WH and Range, see Table G2413.4(1). (The segment from the gas pack to the WH T) 3. The length is measured from the meter to the furthest attached appliance for sizing the pipes, G2413.4.1. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 11/08/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |