Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1123-09229
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/20/2023 | Site Engineering | NOT REQUIRED | |||
11/20/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
11/20/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-1123-09229 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. SITE PLAN: 1. Indicate the location and size of proposed structure, existing buildings, and utility meters, R106.1.1. STRUCTURAL PLANS: 1. Provide a Roof Framing Plan showing the location and size of beams, headers, and rafters for supporting live and dead structural loads, R804. SECTIONS - DETAILS: 1 Show a complete cross-section detail with post to beam fabricated hardware, R407.3 & R507.4.1. 2 Identify all fasteners for wind loading compliance. Show ledger to wall fasteners with appropriate structural rating, R802. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
||
11/08/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-1123-09229 9311 East 8th Street – R-1 Porch/awning (1st Review) TRANSMITTAL DATE: November 8, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 1. Provide a site plan meeting the residential plot plan requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf. Refer to permit number T15CM00970 for an example site plan affiliated with the property: https://pro.tucsonaz.gov/permitdetails/T15CM00970/. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
11/06/2023 | PDSD Application Completeness | REVIEW COMPLETED |