Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-1123-09222
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/26/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/26/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1) Provide PV interconnection in compliance with NEC 705.12. See NEC 705.12(B)(2)(1) a-b. The #3 awg Cu feeder conductor is undersized for this Feeder tap. or the 125A subpanel breaker is oversized for the rating of the conductor. building_official@tucsonaz.gov |
||
| 04/24/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |