Permit Number: TC-RES-1122-01173
Parcel: 135100940

Address:
7133 E 34TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1122-01173
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/02/2022 Site Engineering NOT REQUIRED
12/14/2022 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/14/2022 Residential Building REQUIRES RESUBMIT 1. Provide a permit number for the bedroom at property line or include detailed plans showing one hour fire rating construction and complete code compliance.
2. Update detail #5 showing compliant roof/ceiling insulation with a minimum R-5 rigid later at the sheathing. Perhaps detail #5 & 6 are mislabeled on the plan.
3. Show the clothes washer drain connection on sheet #3 and remove the gray water notation.
4. Show a minimum 1" yard water pipe size (new or existing) for supporting the building water demand.
12/06/2022 Site Zoning REQUIRES RESUBMIT ShapeShape

FROM: PDSD Zoning Review





PROJECT:



TC-RES-1122-001173

7133 E 34th St – R-1

Attached Sleeping Quarters (1st Review)





TRANSMITTAL: December 06, 2022

Per UDC Article 4.9.7.B.7 For any new single-family dwelling in the R-1 zone with five bedroom, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom. For all single-family dwellings in the R-1 zone with five or more bedrooms, and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used. Show the required 5 vehicle parking spaces in the side or read yard and demonstrate that the required dustproofing is provided.



Provide a perimeter yard setback dimension from the midpoint of the west wall to the west property line, see UDC Article 6.4.5.B.5. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).



Provide perimeter yard setback dimensions from the unpermitted bathroom and storage to the east property line. This setback may be averaged, see UDC Article 6.4.5.B.5. Minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line



Provide a perimeter yard setback dimension from the laundry room to the north property line.



If the above perimeter yard setbacks do not meet the minimum setbacks a Design Development Option will be required to reduce the setback.




If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
12/01/2022 PDSD Application Completeness Express REVIEW COMPLETED