Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.2
Permit Number - TC-RES-1122-01121
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/21/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/21/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-1122-01121 (3932 N PALM GROVE DR TUCSON, AZ 85705) All code references are to 2018 International Residential Code. PLUMBING Plans: 1. Note and specify all piping materials and sizes, P2609. a. Missing pipe materials and size for new pipe line. 2. Specify developed length. a. Missing developed length. Length is pipe length measured from gas meter to furthest appliance. 3. Use Table G2413.4(1) to calculate correct required pipe sizes. a. New Pipe is missing sizing information. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 03/13/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |