Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-1122-00992
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/20/2022 | Light Residential Building Review (OIP) | APPROVED | |||
| 12/20/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/06/2022 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-RES-1122-00992 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied Please make corrections and resubmit. Resubmittal shall include a response letter. All code references are to those recognized by the 2018 IRC, City of Tucson Amendments to the 2018 International Residential Code" and "PV System Requirements" adopted by City of Tuscon unless otherwise noted. Recommend clouding changes to speed up the rereview. 1. Provide note: "All code references to those recognized by the City of Tucson" as per PV System requirements adopted by City of Tuscon. 2. Sheet "ARRAY PROFILE" and "STRUCTURAL LAYOUT" indicates "S-TILE" as roofing material. a. Verify class of roofing as per IRC-905. b. Verify installation as per manufacturer's installation instructions. c. Verify weight of roofing material is calculated for roof dead load as per PV System requirements adopted by City of Tuscon. 3. Provide a lag-bolt connection up-lift calculation demonstrating the wind load supporting capability, R301.1. 4. Show the size and total number and spacing of lag bolts as per PV System requirements adopted by City of Tuscon. 5. Verify manufacturer's installation requirements-minimum diameter lag screws with minimum embedment into the rafter are used, or the anchor fastener recommended by the manufacturer’s guidelines, whichever is more stringent as per PV System requirements adopted by City of Tuscon. 6. Verify roof is capable of supporting the weight of the following: a. Existing roof structural members sized as required for roof span and corresponding dead load(s) with existing sheathing. b. S-TILE as per Sheet "ARRAY PROFILE" and "STRUCTURAL LAYOUT". c. Proposed and existing PV roof top solar system(s). d. Live load(s) of person(s) servicing solar system and or firefighters accessing roof. e. Buildings and structures, and parts thereof, shall be constructed to safely support all loads, including dead loads, live loads, roof loads, flood loads, snow loads, wind loads and seismic loads as prescribed by this code as per IRC-R301.1. 7. Provide documentation to verify the weight of the PV system 4 lbs/sq ft. or less as per IRC. 8. Provide documentation to verify the attachment points of the mounting system are staggered (no check requires low snow and wind load location). 9. Verify Structural Requirements-Rooftop-mounted photovoltaic panel systems shall be designed to structurally support the system and withstand applicable gravity loads in accordance with Chapter 3. The roof on which these systems are installed shall be designed and constructed to support the loads imposed by such systems in accordance with Chapter 8 as per IRCR324.4.1. 10. Provide a lag-bolt connection up-lift calculation demonstrating the wind load supporting capability, R301.1. Show the size and total number and spacing of lag bolts as per PV System requirements adopted by City of Tuscon. Verify manufacturer's installation requirements-minimum diameter lag screws with minimum embedment into the rafter are used, or the anchor fastener recommended by the manufacturer’s guidelines, whichever is more stringent as per PV System requirements adopted by City of Tuscon. 11. Provide required inspections as per City of Tucson Development Services Department. BUILDING REVIEW COMMENTS: Denied Please make corrections and resubmit. Resubmittal shall include a response letter. All code references are to those recognized by the 2018 IRC, City of Tucson Amendments to the 2018 International Residential Code" and "PV System Requirements" adopted by City of Tuscon unless otherwise noted. Recommend clouding changes to speed up the rereview. 1. Provide note: "All code references to those recognized by the City of Tucson" as per PV System requirements adopted by City of Tuscon. 2. Sheets "ARRAY PROFILE" and "STRUCTURAL CALCS FOR TYP. PANEL LENGTHS" indicates "TILE" at roof. a. Verify class of roofing as per IRC-905. b. Verify installation as per manufacturer's installation instructions. c. Verify weight of roofing material is calculated for roof dead load. 3. Verify Roof penetrations are flashed and sealed in accordance with Chapter 9 as per IRC-R324.4.3. 4. "PLOT LAYOUT and ROOF PLAN" sheets show "FIRE ACCESS PATHWAY PER 2018 IFC/IRC 324.6" but do not provide required dimension(s). Provide dimensions at both gable end perimeters and peak of roof. Show compliance with the 2018 International Fire Code 1204.2.1.1 with a 36” wide access pathway from the eave to the ridge on both sides of the building when the roof slope is greater than 2:12 as per PV System requirements adopted by City of Tuscon. 5. Sheet "ARRAY PROFILE" shows "PEGASUS TILE REPLACE MOUNT SYSTEM' w/ 2 SPAX LAGS PER STANDOFF. LAG INTO WOOD FRAMING, CAULK at TILE & ROOF DECK PENETRATIONS" but does not specify weather sealing. Sheet #8 of 10 Specs show "Everest Ground Lug-Technical Sheet" but does not specify weather sealing. Provide the attachments’ weather sealing detail in compliance and in according to building code IRC section R909.3 and product installation instruction and verifying roof penetrations are flashed to prevent moisture from entering the roof. (IRC Chapter 9, Section R903, R324.4.3). 6. Sheet #7 of Specifications labeled "FIRE RATING" specifies manufacturer's specific criteria required to maintain a Class A fire rating. Verify the module/mounting system combination achieves the required fire classification as per IRC and Rooftop mounted PV panels and modules have the proper fire classification rating. (IRC Section R324.4.2 ). 7. Verify Roof access points, paths and clearances needed to comply with the IFC & IRC as per PV System requirements adopted by City of Tuscon. 8. Verify All roofs have an access point that does not place ground ladders over openings such as windows or doors, are located at strong points of building construction, and in locations where the access point does not conflict with overhead obstructions such as tree limbs, wires, or signs. (IFC 605.11.3.1) as per PV System requirements adopted by City of Tuscon. 9. Sheet "STRUCTURAL LAYOUT" shows trusses @ 24" O.C. with maximum span of 17'-0" but does not show maximum permitted deadload of existing truss. Please verify the maximum permitted deadload of the existing truss. 10. Verify PV systems shall be designed and installed in accordance with Sections R324.3.1 through R324.7.1, NFPA 70 and the manufacturer's installation instructions as per IRC-R324.3. 11. Sheet "STRUCTURAL LAYOUT" does not have attachments staggered throughout. Provide documentation to verify the attachment points of the mounting system are staggered as per PV System requirements adopted by City of Tuscon. 12. Provide Fire Classification-Rooftop-mounted photovoltaic panel systems shall have the same fire classification as the roof assembly required in Section R902 as per IRC-R324.4.2. 13. All sheets of drawings and specifications should be numbered and labeled on Title Block Cover Sheet with "List of Drawings" for identification purposes. 14. Provide required inspections as per City of Tucson Development Services Department. MECHANICAL REVIEW COMMENTS: N/A ELECTRICAL REVIEW COMMENTS Denied Please make corrections and resubmit. Resubmittal shall include a response letter. All code references are to those recognized by the 2018 IRC, City of Tucson Amendments to the 2018 International Residential Code" and "PV System Requirements" adopted by City of Tuscon unless otherwise noted. Recommend clouding changes to speed up the rereview. 1. Provide note: "All code references to those recognized by the City of Tucson" as per PV System requirements adopted by City of Tuscon. 2. Provide the exact wording and locations for any plaques which may be required for non co-located disconnects as per "PV System Requirements" adopted by City of Tuscon. 3. Show the back feed breaker at the opposite end on the panelboard from the main feeder location and label “Do Not Relocate”, NEC 705.12 (B)(2)(3) as per "PV System Requirements" adopted by City of Tuscon. 4. Clarify where the "Rapid Shut Down" occurs on the line diagram(s) which are required to be identified in each component and circuit notating sizes and installation details (labeling locations) as per PV System requirements adopted by City of Tuscon. (Typically, between solar modules and inverters) 5. Provide third party electric plan approval from electrical underwriter. 6. Provide electric plan approval from Tucson Electric Power (TEP) Electric Utility provider. 7. Provide an appropriate Maximum Photovoltaic System Voltage (Voc x 1.14) NEC 690.7 and Table 690.7 (16 degrees F lowest ambient). Show a collector panel design with a corrected voltage maximum not exceeding 600 volts. Show an inverter with appropriate specifications for this calculation. 8. Provide the exact wording and location for the Power Source “Imp, Vmp, Vmax, Isc, Wmax” marking required by NEC 690.51. Provide identification of polarity, max. overcurrent device rating for module protection and with the following ratings: a. Open-circuit voltage b. Operating voltage c. Maximum permissible system voltage d. Operating current e. Short-circuit current f. Maximum power 9. Sheet of "3-LINE ELEC. DIAGRAM" shows (1) #10 E.G.C. (Equipment Grounding Conductor). AC and DC grounding electrode conductor size must be equal to the DC supply conductors and not smaller than #8 (copper), NEC 690.47(A) and NEC 250.166 & 690.47(B) as per PV System requirements adopted by City of Tuscon. PLUMBING REVIEW COMMENTS: N/A If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
| 11/25/2022 | PDSD Application Completeness Express | REVIEW COMPLETED |