Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1122-00962
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/16/2022 | Site Engineering | NOT REQUIRED | |||
| 12/08/2022 | Site Landscape | NOT REQUIRED | |||
| 12/16/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/12/2022 | Residential Building | REQUIRES RESUBMIT | SITE PLAN: 1. Show the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. Identify the utility lines requiring upgrade or replacement. SECTIONS - DETAILS: 1. Show the minimum 12” footing depth below the undisturbed ground surface with 12” minimum width for wood framed walls in a proposed continuous footing, R403.1. 2. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5), a ½” diameter anchor bolt with a minimum 7" embedment, R602.10.8 & R403.1.6. ELECTRICAL PLANS: 1. Protection of all interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors requires combination type arc-fault circuit interrupters, E3902.16. |
||
| 12/05/2022 | Site Zoning | REQUIRES RESUBMIT | ShapeShape FROM: PDSD Zoning Review PROJECT: TC-RES-1122-00962 5971 S Springbrook Dr – R-2 Enclose Porch to Rooms (1st Review) TRANSMITTAL: December 05, 2022 This site is located in the R-2 zone (UDC 4.9.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-4), subject to Use Specific Standards 4.9.7.B.6, .9, & .10. Remove the aerial photo from the plot plan. Remove all references to Hillside, Pima County and grading from the plan as none of these are applicable to this site. There appears to be a perimeter yard setback line on the plans but it does not appear to be correct. Remove this line from the plan and provide a setback dimension from the proposed porch enclosure to the north, south and east property lines. Review UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf, and provide a lot coverage calculation. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 12/01/2022 | PDSD Application Completeness Express | REVIEW COMPLETED |