Permit Number: TC-RES-1122-00954
Parcel: 125030360

Address:
2939 E 3RD ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1122-00954
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/13/2022 Historic NOT REQUIRED Subject property is located within the Sam Hughes National Register historic district, but not within a Historic Preservation Zone (HPZ) so no Historic review required. Additionally, the carport appears to be more recent construction. There is no requirement for the Historic Demolition Application due to the age.
12/02/2022 Site Engineering NOT REQUIRED
12/08/2022 Site Landscape NOT REQUIRED
12/13/2022 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/12/2022 Residential Building REQUIRES RESUBMIT SITE PLAN:

1. Show the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. Identify the utility lines requiring upgrade or replacement.

FLOOR PLANS:
1. Show the (carport roof) structure with one-hour fire-resistive wall construction parallel with the neighboring property line in compliance with IBC Table 721.1(2) or provide a clear 3’ fire separation distance between the property line and the structure. This construction or separation is required from ground to roof and from end to end of the roof which resists fire spread across the property line.
12/05/2022 Site Zoning REQUIRES RESUBMIT ShapeShape

FROM: PDSD Zoning Review





PROJECT:



TC-RES-1122-00954

2939 E 3rd St – R-1

Attached Carport (1st Review)





TRANSMITTAL: December 05, 2022

This site is located in the R-1 zone (UDC 4.9.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-4), subject to Use Specific Standards 4.9.7.B.5 - .9.



As the existing carport was demolished and you are proposing to expand the size of the carport the following comments apply:



The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).



Per UDC Article 6.4.5.B.2 measurement of wall height for a carport structure is based on a vertical structural member(s) (i.e., post, column, dormer wall) supporting a roof extension from the principal structure is considered a wall for applying perimeter yard requirements. Based on the 10’-0” height provided on the elevations the required perimeter yard setback from the post supporting the carport to the west property line is 6’-8”. As no perimeter yard setback dimension was provided from the post to the west property line Zoning cannot determine what process will be required to reduce the west perimeter yard setback. Provide a perimeter yard setback from the face of the post supporting the carport to the west property line on the plot plan. If this setback is less than 1’-0” a Board of Adjustment for Variance will be required to reduce the setback. If the setback is 1’-0” or great a Design Development Option (DDO) will be required to reduce the setback.



Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf.



DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf.



Until the comment above has been addressed Zoning cannot determine what process is required and cannot provide the required comments for the process.


If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
12/01/2022 PDSD Application Completeness Express REVIEW COMPLETED