Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1122-00850
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/28/2022 | Site Landscape | APPROVED | |||
| 12/21/2022 | Site Engineering | NOT REQUIRED | |||
| 01/03/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/03/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Planner PROJECT: TC-RES-1122-00850 1517 W Saint Clair St – R-2 ADU (1st Review) TRANSMITTAL DATE: January 3, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is in the R-2 zone (UDC 4.7.9). An ADU is a permitted use in the R-2 zone, subject to use-specific standards 4.9.7.B.6, .8 & .9, and 6.6.3. The following comments may be relative to an application for a Board of Adjustment variance (UDC 3.10.3). 1. Add a general note on the cover sheet stating that the ADU will be developed with a high albedo level (>60 SRI) or other cool roof technology per the ICC Green Construction Code (UDC 6.6.3.B.3). 2. Provide measurements from design grade (the ground) to the highest point of each wall. Per UDC Table 6.3-2.A, the required setback is 6’-0”, or 2/3 the height of the proposed exterior building wall, whichever is greater. Demonstrate on the elevations that the height of the casita, measured from design grade to the highest point of each wall, does not exceed 10’-6”. 3. Detached accessory buildings, including accessory dwelling units, are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line (UDC 6.6.3.C). Per a Zoning Administrator’s determination dated December 1, 2008, the ADU may be considered attached to the principal building if a five-foot-wide connection that can support a 20-pound live load is constructed. The latticed breezeway as shown on the submitted plans does not meet this attachment requirement. A Board of Adjustment variance is required to allow the construction to be detached in the front yard. Contact Mark Castro at Mark.Castro@tucsonaz.gov should you have questions regarding the variance process. If you have any questions about this transmittal, contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 12/20/2022 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 12/22/2022 | Residential Building | REVIEW COMPLETED |