Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1122-00822
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/02/2022 | Site Engineering | NOT REQUIRED | |||
| 12/08/2022 | Site Landscape | NOT REQUIRED | |||
| 12/12/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/12/2022 | Residential Building | REQUIRES RESUBMIT | GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits SITE PLAN: 1. Show the location of utility lines on the property, R106.1.1. Identify the utility lines requiring upgrade or replacement (i.e., Overhead Electrical Line). FOUNDATION PLAN: 1. Show #4 rebar reinforcement with 3” clearance from earth, R403.1.3.5.3. Provide ½” anchor bolts with 7” embedment, R403.1.6. FRAMING PLAN: 1. Provide a complete roof framing plan with beams and rafters sized with appropriate load carrying capacity, R301.1. Show 4x8 beams. SECTIONS - DETAILS: 1. Show the Post Section Detail with #4 rebar in the footing, R403.1. 2. Show any ledger fasteners with stucco removal between wall studs and ledger. 3. The roof structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the porch roof within 3 feet to the neighboring property line or provide a complete wall barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2). Please contact the plans reviewer if you have any questions: Ken Van Karsen 520 837-4912 City of Tucson Residential Plan Review |
||
| 12/05/2022 | Site Zoning | REQUIRES RESUBMIT | ShapeShape FROM: PDSD Zoning Review PROJECT: TC-RES-1122-00822 4642 E Calle Aurora – R-1 Covered Porch Addition (1st Review) TRANSMITTAL: December 05, 2022 This site is located in the R-1 zone (UDC 4.9.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-4), subject to Use Specific Standards 4.9.7.B.5 - .9. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 12/01/2022 | PDSD Application Completeness Express | REVIEW COMPLETED |