Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-1122-00792
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/16/2022 | Light Residential Building Review (OIP) | APPROVED | |||
| 12/16/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/09/2022 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-RES-1122-00792 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied NEED THE ENGINEER'S STRUCTURAL ANALYSIS REPORT FOR THE ADDITION OF THE EQUIPMENT AND THE EXISTING BUILDING. NEED THE RACKING INSTRUCTIONS INCLUDING THE GROUNDING/BONDING DETAILS AND DIAGRAM. NEED THE RACKING MOUNTING BRACKET DETAILS, SPEC SHEETS, AND INSTRUCTIONS. BUILDING REVIEW COMMENTS: Denied NEED THE ENGINEER'S STRUCTURAL ANALYSIS REPORT FOR THE ADDITION OF THE EQUIPMENT AND THE EXISTING BUILDING. NEED THE RACKING INSTRUCTIONS INCLUDING THE GROUNDING/BONDING DETAILS AND DIAGRAM. NEED THE RACKING MOUNTING BRACKET DETAILS, SPEC SHEETS, AND INSTRUCTIONS. NEED A DOCUMENT SHOWING THE MODULE COMPATIBILITY FROM THE RACKING MANUFACTURER. VERIFY EQUIPMENT IS READILY ACCESSIBLE AS REQUIRED BY UTILITY COMPANY AND EMERGENCY PERSONNEL. DETAIL VEHICLE IMPACT PROTECTION AS NEEDED MECHANICAL REVIEW COMMENTS: N/A ELECTRICAL REVIEW COMMENTS Denied NEED THE ENGINEER'S STRUCTURAL ANALYSIS REPORT FOR THE ADDITION OF THE EQUIPMENT AND THE EXISTING BUILDING. NEED THE RACKING INSTRUCTIONS INCLUDING THE GROUNDING/BONDING DETAILS AND DIAGRAM. NEED THE RACKING MOUNTING BRACKET DETAILS, SPEC SHEETS, AND INSTRUCTIONS. NEED A DOCUMENT SHOWING THE MODULE COMPATIBILITY FROM THE RACKING MANUFACTURER. DETAIL THE CIRCUITS AND LOADS BEING RELOCATED TO THE BACKUP PANEL. SHOW ALL REQUIRED LABELS INCLUDING RACEWAYS FOR DC CONDUCTORS PER SECTION 690.31(G)(3), BACKFED BREAKER AND OCPD LABELS REQUIRED BY SECTION 705.12(B)(2), ETC. THE NEUTRAL AND GROUND ARE NOT SHOWN BONDED IN THE ELECTRICAL DIAGRAM OF THE MAIN DISCONNECT PANEL. VERIFY EQUIPMENT IS READILY ACCESSIBLE AS REQUIRED BY UTILITY COMPANY AND EMERGENCY PERSONNEL. DETAIL VEHICLE IMPACT PROTECTION AS NEEDED. PLUMBING REVIEW COMMENTS: N/A If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
| 11/23/2022 | PDSD Application Completeness Express | REVIEW COMPLETED |