Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1122-00766
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/01/2022 | Site Engineering | NOT REQUIRED | |||
| 12/01/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/01/2022 | Residential Building | REQUIRES RESUBMIT | 1. Show a ½” gypsum board (garage side) on all walls common to the garage and house or other fire rated product in compliance with R302.6. Add the garage side gypsum notation at existing wall to the window enclosure detail. 2. Show braced wall panel compliance for (narrow) framed walls with a garage door opening, Table R602.10.5. For prescriptive braced wall structures show a portal frame with hold-downs PFH method, Figure R602.10.6.2, or a portal frame at garage door PFG method, Figure R602.10.6.3, or a continuously sheathed portal frame CS-PF method, Figure R602.10.6.4. Add a detail showing required structural features. |
||
| 12/01/2022 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-RES-1122-00766 8440 E KENT PL Zoning R-1 TRANSMITTAL DATE:December 1, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Remove the note that states “Not for construction check print only” 2. COMMENT: Draw dimension and label the height of the proposed garage structure measured from design grade to top of wall. 3.COMMENT: Clarify if the existing garage is to be left as a garage or if it is going to be converted into a bedroom 4.COMMENT: Clearly show everything on site. Based on current aerial photos there is a couple of detached structure on the southeast portion of the property. Please provide the setback dimension, include these structures in the lot coverage. Additional comments may be forth coming. 5. COMMENT: It appears that these unpermitted structures will not be meeting the required setback. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). At a minimum, a neighbor’s setback waiver is required to reduce the perimeter yard setback. To secure this waiver the following text shall be provided on the plot plan and be signed and dated by the owner of the property affected. : My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ If you are unable to secure the neighbor’s setback waiver a Design Development Option (DDO) will need to be processed and approved to reduce the setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted: https://tdc-online.tucsonaz.gov/#/ If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 12/01/2022 | PDSD Application Completeness Express | REVIEW COMPLETED |