Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1122-00601
Parcel: 112032280

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-1122-00601
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/06/2023 Historic NOT REQUIRED This property is a contributing resource to the Winterhaven National Register Historic District. It is not located within a HPZ. Historic review is not required. To ensure retention of contributing status, applicant should talk to SHPO at azshpo@azstateparks.gov.
02/23/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/09/2023 Site Engineering REQUIRES RESUBMIT Per comment from Jodie Brown, show proposed addition will maintain historic contribution status (this will waive any floodplain regulatory requirements). If historic status lost, please submit a cost-estimate for the project on TE-FPU-0223-00088

Scott Haseman
scott.haseman@tucsonaz.gov
02/15/2023 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review

PROJECT: TC-RES-1122-00601
2564 E Kleindale Rd - R-1
Convert Garage to Bedroom (2nd Review)

TRANSMITTAL: February 15, 2023

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

This comment was not addressed correctly. The required vehicle parking spaces are not allowed in the front yard and must be located in the side or rear yard. Based on the definition of a Bedroom, The term bedroom includes all of the following: 1) Any room that is designated as a bedroom; 2) Any enclosed room that has a minimum area of 60 square feet and has an accessible opening to the exterior of the building in compliance with the International Building Code (IBC), whether termed a studio, family room, study, den, bonus room, or any other name, except for a living room, dining room, kitchen , and bathrooms; and 3) Any room designated as a bedroom for the purpose of any other code requirement, see UDC Article 11.4.3, the proposed “FLEX’RM.” is considered a bedroom making the total number of bedrooms on this site five (5).. Based on UDC Article 4.9.7.B.7 For any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom. For all single-family dwellings in the R-1 zone with five or more bedrooms, and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used. Show the required three (3) vehicle parking spaces in the side or rear yard and demonstrate that the required dust control is met.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
02/07/2023 Fire New Construction REVIEW COMPLETED
02/03/2023 PDSD Application Completeness Express REVIEW COMPLETED
02/23/2023 Residential Building REVIEW COMPLETED