Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-1122-00594
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/12/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/05/2022 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-RES-1122-00594 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied PENDING THE RESUBMITTAL OF THE ELECTRICAL AND BUILDING REVIEWS BUILDING REVIEW COMMENTS: Denied NEED RACKING ASSEMBLY SPEC SHEETS/ INSTALLATION INSTRUCTIONS. NEED A DOCUMENT VERIFYING THE MODULE IS ALLOWED PER THE RACKING COMPANY. MECHANICAL REVIEW COMMENTS: N/A ELECTRICAL REVIEW COMMENTS Denied NEED RACKING ASSEMBLY SPEC SHEETS/ INSTALLATION INSTRUCTIONS. NEED A DOCUMENT VERIFYING THE MODULE IS ALLOWED PER THE RACKING COMPANY. NEED OCPD AND WIRE RATING CALCULATIONS FOR HIGH AND LOW TEMPERATURES, NUMBER OF WIRES IN CONDUIT, ETC PLUMBING REVIEW COMMENTS: N/A If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
| 12/12/2022 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit: TC-RES-1122-00594 Address: 2410 S Layton Pl After comparing the aerials to the plot plan, it has come to my attention that there is a possible non-permitted addition on the Southeast portion of the house near the driveway. Upon reviewing permit history on PRO (https://pro.tucsonaz.gov/), I was not able to verify a permit for this addition. Please relocate your solar panels to a permitted portion of the house or obtain permits for your new addition. This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TI’s and solar). Construction of separate builds/new structures does not require a cost estimate to be provided. Instructions: 1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub -Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record 2. Locations -> Confirm the location is accurate to the project. Click “Next” 3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next” 4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next” 5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next” 6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next” 7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next” 8. Review and Submit -> Review all information to ensure accuracy. Click “Submit” Contact Scott Haseman at scott.haseman@tucsonaz.gov, Stephen Blood at Stephen.Blood@tucsonaz.gov, or Loren Makus at Loren.Makus@tucsonaz.gov if you have any questions about the FUP. |
||
| 11/17/2022 | PDSD Application Completeness Express | REVIEW COMPLETED |