| 01/20/2023 | Site Engineering | NOT REQUIRED | |||
| 01/23/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/21/2022 | Residential Building | REQUIRES RESUBMIT | |||
| 01/23/2023 | Site Landscape | REQUIRES RESUBMIT | Resubmit plans when hold is removed. | ||
| 12/06/2022 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Planner PROJECT: TC-RES-1122-00533 4102 E Whittier St – R-1 Sleeping quarters (1st Review) TRANSMITTAL DATE: December 6, 2022 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. The following comments are relative to an application for a Board of Adjustment variance (UDC 3.10.3). 1. Indicate the square footage of the existing detached accessory sheds on the cover sheet or the site plan. The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure. Accessory structures less than 200 square feet gfa and accessory dwelling units are exempt from this requirement (UDC 6.6.3.E). If the total gfa of all accessory structures exceeds 50%, a Board of Adjustment variance is required. 2. Show the square footage of the vehicular use area. Lot coverage includes the area of the site covered with buildings, vehicular use areas, and storage areas (UDC 6.4.3.B.3). Demonstrate that lot coverage does not exceeding 70% as required by UDC Table 6.3-2.A. 3. A detached mobile storage container appears in aerial photography and Google Street View beginning in 2021. This storage container may be within the right-of-way. Clarify what will happen to or what has happened to this storage container. 4. Per UDC 6.4.5.C.1.b, where a lot abuts more than one street, the owner chooses which street lot line is the front lot line. From other than the front lot line, the street perimeter yard is ten feet. Provide a dimension from the centerline of Irving Avenue to the side street property line showing a 30-foot distance. Additionally, show a dimension from the west property line to the proposed west building wall demonstrating a ten-foot setback. 5. Provide a floor plan of the existing single-family dwelling to ensure compliance with UDC 4.9.7.B.7. For any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom. For all single-family dwellings in the R-1 zone with five or more bedrooms, and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used. 6. For residential uses, accessory structures, except for accessory dwelling units, shall not exceed 12 feet in height, unless attached to a principal structure. The building height of the proposed detached accessory structure exceeds 12 feet in height and requires a Board of Adjustment variance to exceed this height requirement. 7. Per UDC 6.4.5.B.1, a setback is the distance measured horizontally from the property line to the face of each exterior building wall at the wall’s highest point. Per UDC Table 6.3-2.A: Dimensional Standards for the R-1, R-2, R-3, MH-1, & MH-2 Zones, when a residential use is adjacent to a residential zone, the required setback is six feet, or 2/3 the height of the proposed exterior building wall, whichever is greater, measured from the building wall to the property line. For your reference, roof overhangs may extend two feet into the setback (UDC 6.4.5.D.1.b). Clearly provide elevations measured from design grade to the highest point of each exterior wall to determine whether perimeter yard setbacks are being met. If setbacks are not being met for the proposed detached accessory structure, the Board of Adjustment variance process may also reduce these setbacks. The Board of Adjustment variance application and requirements can be found at this link: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf. Please ensure the variance application is submitted as “Additional/Supporting Documentation” under this activity number. Contact Mark Castro at Mark.Castro@tucsonaz.gov should you have questions regarding the DDO process. 8. Further Zoning comments may be forthcoming with your next submittal. If you have any questions about this transmittal, contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 12/02/2022 | PDSD Application Completeness Express | REVIEW COMPLETED |