Review Date Reviewer's Name Type of Review Description Status Comments
04/17/2023 Site Zoning NOT REQUIRED
04/17/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/04/2023 Residential Building REQUIRES RESUBMIT Show the location of the proposed service panel. TEP usually requires the shorted distance to the transformer.

Show if the proposed service panel is a new single or dual meter base.

Show any replaced feeder conductors to existing sub panels. All interior alterations require a floor plan for review. An interior subpanel requires a clear working space of 30” wide x 36” deep, E3405.2 and panelboards shall not be in clothes closets, in bathrooms, or over the steps of a stairway, E3405.5.
03/17/2023 PDSD Application Completeness Express REVIEW COMPLETED