Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-1122-00406
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/19/2023 | Historic | NOT REQUIRED | Property is located within Rincon Heights National Register Historic District which is not an HPZ. No Historic review required. | ||
01/03/2023 | Site Engineering | NOT REQUIRED | |||
01/31/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
01/12/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-1122-00406 1532 E 9th St – R-2 ADU (1st Review) TRANSMITTAL DATE: January 12, 2023 COMMENTS: The following comments are relative to an application for a Design Development Option (UDC Section 3.11.1). Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Until approved by Historic & DDO the following comments apply: 1. Clarify whether the covered structure in the rear of the detached garage is being demolished. As the structure appears in aerial photography as early as 1958, historic approval to demolish the structure is required. Buildings, portions of buildings, or structures that are 50 years of age or older must be architecturally documented prior to demolition. Documentation will be reviewed and approved by the Historic Preservation Office before a permit is issued. Demolition (Historic and Older Structures) Application and General Information may be downloaded (PDF) at https://www.tucsonaz.gov/files/pdsd/Preservation/Historic_Demolition_Application_Form.pdf. Submit the completed application as “Additional/Supporting Documentation” for this permit number. 2. The required side and rear perimeter yard setbacks are 6’-0”, or 2/3 the height of the building wall, whichever is greater (UDC Table 6.3-2.A). Based on a wall height of approximately 12’-8”, measured from design grade (the ground) to the highest point of the building wall, the required side perimeter yard setback to the east lot lines is 8’-4”; proposed is 6’-0”. Design Development Option (DDO) approval is required to reduce the side and rear perimeter yard setbacks. The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/2019_DDO_for_Setback_and_Height_UDC.pdf. The DDO application shall be submitted as “Additional/Supporting Documentation” under this existing activity number. Contact Mark Castro at Mark.Castro@tucsonaz.gov should you have questions regarding the DDO process. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
01/09/2023 | Zoning Modifications - DDO | REQUIRES RESUBMIT | A Design Development Option (DDO) must be submitted and approved to reduce the required setback. The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/2019_DDO_for_Setback_and_Height_UDC.pdf. Please contact me at Georgia.Pennington@tucsonaz.gov or at 520-837-6311 should you have questions about this transmittal. |
||
01/03/2023 | PDSD Application Completeness | REVIEW COMPLETED | |||
01/31/2023 | Residential Building | REVIEW COMPLETED |