Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/01/2022 | Site Engineering | NOT REQUIRED | |||
12/01/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
11/22/2022 | Residential Building | REQUIRES RESUBMIT | TC-RES-1122-00378 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Structures built without a permit may require alteration for building code compliance. Provide a clear and concise construction plan set. Sample drawings are shown as an example: https://www.tucsonaz.gov/pdsd/residential-permits SITE PLAN: 1. Indicate the location and size of buildings, utility meters and lines supporting the alterations, R106.1.1. Show the utility lines requiring upgrade or replacement. FLOOR PLANS: 1. Identify the wall material between dwelling and proposed storage room for required fire spread separation (½” GWB equivalent), R302.6. STRUCTURAL PLANS: 1. Provide a Roof Framing Plan showing the location and size of all beams, headers, and rafters for supporting live and dead structural loads, R804. SECTIONS - DETAILS: 1 Show a cross-section detail of the proposed exterior wall, R106.1.1. Show 3/8” structural or ½” non-structural wall sheathing of the proposed exterior wall, R106.1.1. 2 Show a complete cross-section detail of the new exterior wall, R106.1.1. Show the minimum 12” x 12” continuous #4 rebar reinforced footing, R403.1. Show with dimensions the exterior wood siding, insulation, interior sheathing, and pressure treated sill anchored with ½” x 10” bolts. Show the wall assembly with a 6” clearance above the ground or 2” clearance above an exterior concrete surface, R317.1 item 5. 3 The framed wall may require a concrete stem for achieving the 6” clearance between framing and ground (R317.1 item 5). 4 Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. ELECTRICAL PLANS: 1. Branch Circuit: a separate (dedicated) GFCI 20-amp branch circuit required for receptacles in an attached garage/storage, E3703.5. 2. Receptacle Location: an outlet is required at each vehicle bay not more than 5.5 feet above the floor, E3901.9. 3. Show at least one wall-switch-controlled lighting outlet providing illumination on the exterior side of each egress door having grade level access R3903.3 If you have any questions, please contact: Ken Van Karsen (520) 791-5550 City of Tucson Residential Plan Review |
||
11/28/2022 | Site Zoning | REQUIRES RESUBMIT | ShapeShape FROM: PDSD Zoning Review PROJECT: TC-RES-1122-00378 8437 E Rosework St - R-1 Attached Storage (1st Review) TRANSMITTAL: November 28, 2022 This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
11/21/2022 | PDSD Application Completeness Express | REVIEW COMPLETED |