Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1122-00358
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/01/2022 | Site Engineering | NOT REQUIRED | |||
| 12/01/2022 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/21/2022 | Residential Building | REQUIRES RESUBMIT | TC-RES-1122-00358 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. SITE PLAN: 1. Update the electric and water lines from meter to building, R106.1.1. Show all utility point of connections without dependance on another dwelling. TEP may require the service panel for the property at the closest building to the service transformer with an underground feeder from a dual meter to the more distant dwelling. SECTIONS - DETAILS: 1. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). This may require a concrete stem when the floor is less than 6” above grade. PLUMBING PLANS: 1. Show an individual water heater for each dwelling unit, P2801.1. 2. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate yard pipe bypassing the existing dwelling and the water meter size. ELECTRICAL PLANS: 1. Smoke alarms are required at each separate sleeping area, R314.3.2. 2. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6. Remove circuit #2 from the kitchenette counter top. 3. Show at least one wall-switch-controlled lighting outlet providing illumination on the exterior side of each egress door having grade level access R3903.3. Please contact the plans reviewer if you have any questions: Ken Van Karsen (520) 837-4912 PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 11/25/2022 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Planner PROJECT: TC-RES-1122-00358 2537 E 21st St – R-1 Detached sleeping quarters (1st Review) TRANSMITTAL DATE: November 25, 2022 COMMENTS: The following comments may be relative to an application for a Board of Adjustment variance (UDC Section 3.10.3). Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Per the Country Club Manor subdivision plat, the correct lot size of the property is 7,168.50 square feet. Provide the correct lot size and lot coverage calculations on the site plan. 2. The rear porch appears in aerial photography beginning in 2008. No permit documentation could be found for this rear porch. Either provide permit documentation for the rear porch or include it within this permit’s scope of work. 3. Per UDC 6.6.3.D, “accessory structures…shall not exceed 12 feet in height, unless attached to a principal structure.” Building height “is the vertical distance measured from the design grade elevation…to the middle (between the eave and ridge) of the highest gable of a pitched or hipped roof” per UDC 6.4.4.A. Provide a measurement on the elevations between the eave and ridge of the detached accessory structure to ensure building height is not exceeding 12 feet. A Board of Adjustment variance is required if the proposed detached accessory structure exceeds 12 feet in building height. If you have any questions about this transmittal, please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 11/21/2022 | PDSD Application Completeness Express | REVIEW COMPLETED |