| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/10/2026 | Residential Engineering | APPROVED | |||
| 11/16/2026 | Residential Zoning | APPROVED | |||
| 11/16/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/05/2026 | Addressing Validation | REQUIRES RESUBMIT | For questions: PDSD-Permits@tucsonaz.gov. The plans submitted for 219 E Palmdale Street contain units 2101 and 2102. These units will have to be assigned to the Permit Application. Please sign into your TDC account and edit the address from BLDG 2 to include units 2101 and 2102. |
||
| 11/10/2026 | Residential Building | REQUIRES RESUBMIT | TC-RES-1026-06076 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review includes architectural, plumbing, mechanical, energy conservation and electrical compliance with the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2024 IRC with amendments and building ordinances for all dwellings. Provide a separate response letter addressing each comment with location of change on the plans. GENERAL COMMENTS: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Building-Codes 1. Plans submitted for a newly constructed one- or two-family dwelling after July 1, 2009, require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549 and 2024 IRC appendix NB. Show the clear solar-ready zone on a roof. Label a double breaker space “For Future Solar Electric” on the panel schedule opposite end from the main/supply side. 2. Plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, require gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. The ordinance revision now requires a gray drain line discharge from one fixture for a one-story dwelling. Show gray line plumbed to an exterior wall above grade when feasible, or a bathing fixture drain looped 3’ beyond an exterior wall below grade before connection to the building drain. Use the appropriate detail at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations SECTIONS - DETAILS: 1. Individual dwelling units require separation with a 1-hour fire-resistance rated assembly without openings, R302.3. Update detail B on sheet 5 with 5/8” Type X on the outside face of the studs in compliance with 703.3 of the 2024 IBC. MECHANICAL PLANS: 1. Identify the device model number providing an adjustable setting and note the minimum continuous setting for providing whole-house mechanical ventilation, R303.4; N1103.6 & M1505.4. 2. Provide makeup air of not less than 100 square inches where a clothes dryer is placed in a closet, M1502.6.1. PLUMBING PLANS: 1. Show an appropriate yard pipe size and water meter size, P2903.7. 2. Show an individual accessible water supply shut off for each proposed dwelling unit, P2903.9.1. 3. Show the water heater rating/capacity for consistence with the electrical circuit size, R106.1.1. ELECTRICAL PLANS: 1. Show a surge-protective device (SPD) as an integral part of or placed immediately adjacent to the service equipment, E3606.5. 2. Provide GFCI protection for appliance receptacle outlets, E3902.14. Include the HVAC equipment. Please contact the plans reviewer if you have any questions: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 11/05/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |