Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-1026-06073
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/02/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/02/2026 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov Please resubmit a comment response letter addressing the following comments along with your plans: 1) Provide water heater model and efficiency rating information 2024 IECC R403.5 2) Provide fuel type and fuel demand for new WH, based on fuel type the following may be required: - Electric: 1) Provide a Load Calc. for the electrical including additional load from the new WH. NEC 220 Part III. Include conductors and all supplemental equipment used to supply the new central unit. 2) Outdoor receptacles supplied by a single-phase branch circuit must have GFCI protection for personnel E3902.3, 210.8(A)(3) - Fuel Gas: 1) Show all altered branches including new demand, pipe materials, and developed length, if applicable. 2) Demonstrate ventilation will be required based on man. specifications. M1307.1 |
||
| 10/30/2026 | PDSD Application Completeness Express | REVIEW COMPLETED | Completeness Check Done |