Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1026-06001
Parcel: 122152590

Address:
2113 N RITA AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.2

Permit Number - TC-RES-1026-06001
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/17/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/17/2026 Residential Building - Standard REQUIRES RESUBMIT After DDO approval provide an Arizona engineer’s calculation, design, and seal for a performance design with the existing construction methods not prescriptively code compliant, 2024 IRC, R301.1.
11/12/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston, Planner

PROJECT: TC-RES-1026-06001
2113 N Rita Av., Tucson, AZ 85716
As-Built Carport (1st Review)
Ref: CE-VIO0726-03151

TRANSMITTAL DATE: 11/12/2026

This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. Comment 1 from the residential zoning review completed on 11/02/26 was not fully addressed. All relevant information is required to be on the site plan. Provide a ‘Full’ site plan that meets the requirements of the following: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Site-Plan-Examples The City doesn’t require a survey provided by a registered professional; however, there are several items missing from the site plan including the lot dimensions, a scale, lot coverage and others that are detailed within the site plan information. If you need me to email you the site plan instructions, please reach out to me. Sometimes extracting information from the website through these comments is difficult.

2. Apply for a Design Development Option (DDO). Based on the site plan submitted, it is highly likely a DDO is required per UDC 6.4.5.D.3.A, which states that the carport may only extend 10’ into the required 20 foot front setback. Per UDC 6.4.5.B.2, this is measured from the property line to the nearest supporting post of the carport.

Here is the link to the DDO application materials: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo-for-setback-and-height.pdf After filling out the application, submit under the Zoning Modification sub-record that has been created. For instructions on how to apply for a sub-record, visit the following link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf A case number will be assigned at the time you submit the DDO application. Please contact Georgia Pennington at georgia.pennington@tucsonaz.gov upon completion of the application, and reach out to her with any questions regarding the DDO process. Note that DDO approval with an appeal period may take approximately 6 weeks.

Important note: the DDO must be approved before resubmitting for this building permit (TC-RES-1026-06001).

3. With the next submission for TC-RES-1026-06001, please provide the following:

a. The DDO Decision Letter
b. Revised Site plan
c. Construction plans (thank you for including the elevations)
d. Response letter addressing all staff comments

4. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
11/06/2026 PDSD Application Completeness Express REVIEW COMPLETED