Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.2
Permit Number - TC-RES-1026-05973
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/16/2026 | Residential Zoning | APPROVED | |||
| 11/12/2026 | Residential Engineering | NOT REQUIRED | |||
| 11/17/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/17/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-1026-05973 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review includes architectural, plumbing, mechanical, energy conservation and electrical compliance with the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 code compliance. Provide a separate response letter addressing each comment with location of change on the plans. Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits PLANS: 1. Show the square footage as calculated from the exterior dimensions, R106.1.1. Update sheets #1, 3 - 7. 2. The plans require either a prescriptive design with 2024 IRC compliance or a performance design with an engineer seal. Provide a structural plan with a registered Arizona engineer seal or remove the structural references from sheet #7 and update the infill Detail C on sheet #10 with a code compliant foundation, R106.1. SECTIONS - DETAILS: 1. Provide a wall section detail with (#4 rebar) reinforced 12” x 12” reinforced foundations for anchoring exterior framed walls with ½” anchor bolts with 7” embedment, R403.1.6. 2. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. Add a reinforced concrete stem to Detail C/10 for code compliance when existing interior and exterior surfaces at the same level. 3. Clarify if the ceiling insulation shown on Detail A/10 is proposed or existing. Identify if additional attic ventilation is required, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2. 4. Update the code reference on Detail A/10 to 2024 IECC. https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes MECHANICAL PLANS: 1. Show the mini-split size for the building demand in accordance with M1401.3, M1601.1. Provide demand calculations in accordance with Manual J standards or show as a deferred submittal. PLUMBING PLANS: 1. Clarify the lettering on sheet 12-2 with appropriate vent and pipe sizes, R106.1.1. This can be shown on sheet 12 without sheet 12-2. ELECTRICAL PLANS: 1. Show a smoke alarm in the bedroom and outside the doorway in the immediate vicinity with an electrical circuit, R314.3. 2. Provide a panel schedule identifying the circuits requiring two pole breakers for supplying 240 volts, E3404.13 & E3706.2 3. Show the Bathroom receptacle with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6. 4. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.21. Add notation to plans. 5. Provide GFCI protection for appliance receptacle outlets, E3902.12 & 14. Include the dishwasher, electric range, clothes dryer, microwave oven and HVAC equipment. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 11/10/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |