| 11/10/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/28/2026 | Residential Building | REQUIRES RESUBMIT | Please review the comments below and resubmit. 1.E3901.4 Countertop and Work Surface Receptacles: islands and peninsular counters may no longer have receptacle outlets placed below the countertop on the cabinet surface. Either provide a vertical assembly listed for countertop (work surface) mounting, or a raceway terminated within the cabinet for future assembly installation 2. Please include the Tucson inclusive home design ordinance to your cover sheet A1.0. 3. Please update the Gas Piping Capacity Table to the 2024 IRC. P2.0 4. Please provide a detail of the chimney and fireplace. R1001.1 5. E3606.5 Surge protection: all services supplying dwelling units shall be provided with a surge-protective device (SPD) installed in accordance with Sections E3606.5.1 through E3606.5.3. If you have any questions, you can reach me at Zane.aouane@tucsonaz.gov |
||
| 11/10/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit Activity Number: TC-RES-1026-05857 (1st Review) Project: New frame and stucco single family residence and site improvements Location: 2789 W BLACK CLOUD CT Review Date: 11/10/2026 Reviewer: John Mounsey – Engineering Associate - Residential Engineering Reviewer Contact: John.mounsey@tucsonaz.gov Residential Engineering comments are as follows: 1. Residential Engineering is unable to review and approve permit TC-RES-1026-05857 until the associated Development Package is reviewed and approved by all reviewers. 2. Please update Sheet A1.0 to reflect COT Inclusive Design and COT Zoning Code 3. Please update Sheet A2.0 to reflect Tucson Inclusive Home design. If you have any questions or concerns, please contact John Mounsey at John.Mounsey@tucsonaz.gov |
||
| 10/28/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston, Planner PROJECT: TC-RES-1026-05857 2789 W Black Cloud Ct, Tucson, AZ 85745 SFR & Attached ADU (1st Review) Ref: Tentative Plan S06-50 TRANSMITTAL DATE: 10/28/2026 This site is located in the RX-1 zone (UDC 4.7.6). A single-family residence is a permitted use in this zone (Table 4.8-1) subject to Use Specific Standards 4.9.7.B.6, .8, & .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Provide a landscape plan. Landscape is required for nearly all new residential development per the City’s Unified Development Code (UDC) Article 7.6.8. The landscape plan shall be added directly to the site plan and does not require a landscape architect. Here is a link to the instructions and sample layouts: https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code 2. Dimension the south and west property lines. Here is a link to the Las Nubes final plat: https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=64056 3. The casita does not demonstrate an exterior pathway. Per the City of Tucson Inclusive Home Ordinance 10463: all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the Accessibility Standards. See also Technical Standards Manual 7-01.4.3 for specifications, including the minimum 4ft-width, slope and permissible composition materials: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-10261 4. Provide the following in the next submission packet: a. Revised site plan b. A response letter addressing all staff review comments. 5. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 10/27/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |