Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-1026-05846
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/28/2026 | Residential Engineering | APPROVED | |||
| 10/26/2026 | Residential Zoning | APPROVED | |||
| 10/28/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/26/2026 | Residential Building | REQUIRES RESUBMIT | TC-RES-1026-05846 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review includes architectural, plumbing, mechanical, energy conservation and electrical compliance with the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2024 IRC with amendments and building ordinances for all dwellings. Provide a separate response letter addressing each comment with location of change on the plans. GENERAL COMMENTS: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Building-Codes 1. Plans submitted for a newly constructed one- or two-family dwelling after July 1, 2009, require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549 and 2024 IRC appendix NB. Show the clear solar-ready zone on a roof or framing plan with a minimum 1-1/4” capped roof penetration routed to the electrical service panel. Label a double breaker space “For Future Solar Electric” on the panel schedule opposite end from the main/supply side. SITE PLAN: 1. Show consistent square footage entries on sheets A-01 and 2, R106.1.1. PLANS: 1. Remove outdated code references at note #22 on sheet 6 and note #2 on 9. 2. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. The threshold condition may be located at the garage/dwelling doorway or at an exterior hinged door. 3. Show braced wall panel compliance for (narrow) framed walls with a garage door opening, Table R602.10.5. For prescriptive braced wall structures show a portal frame with hold-downs PFH method, Figure R602.10.6.2, or a portal frame at garage door PFG method, Figure R602.10.6.3, or a continuously sheathed portal frame CS-PF method, Figure R602.10.6.4. SECTIONS - DETAILS: 1. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Batt insulation may not be in contact with the roof sheathing. 2. Show location and method of flashing all wall and roof intersections, R903.2.1. MECHANICAL PLANS: 1. Provide demand calculations in accordance with Manual J standards along with D and S requirements, M1401.3, M1601.1. 2. Identify the device model number providing an adjustable setting and note the minimum continuous setting for providing whole-house mechanical ventilation, R303.4; N1103.6 & M1505.4. 3. Show impact protection for appliances located in the garage, M1307.3.1. 4. Provide makeup air of not less than 100 square inches where a clothes dryer is placed in a closet, M1502.6.1. PLUMBING PLANS: 1. Show the water heater rating/capacity for consistence with the electrical circuit size, R106.1.1. ELECTRICAL PLANS: 1. Show a surge-protective device (SPD) as an integral part of or placed immediately adjacent to the service equipment, E3606.5. 2. Remove receptacles from the exterior face of island and peninsular cabinets where below the countertop. Either provide a vertical assembly listed for countertop (work surface) mounting, or a raceway terminated within the cabinet for future assembly installation, E3901.4.2. 3. Provide GFCI protection for appliance receptacle outlets, E3902.12 & 14. Include the Dishwasher, Electric range, Clothes dryer, Microwave oven and HVAC equipment. OUTDOOR LIGHTING CODE 1. Show Fixture C as unshielded style and within the property limit with an updated Outdoor Lighting Calculation or change the flood light symbol to a full cut-off style. Adjustable security light fixtures are unshielded, not full cut-off. Please contact the plans reviewer if you have any questions: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 10/23/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |