Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1026-05778
Parcel: 125010740

Address:
174 N FORGEUS AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.5

Permit Number - TC-RES-1026-05778
Review Name: RESIDENTIAL SIMPLE REVIEW v.5
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/02/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/02/2026 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov
Please resubmit a comment response letter and corrected plan set addressing the following comments:
The following comments were not addressed. Please carefully read, provide a comment response letter acknowledging comments, and demonstrate how the comments were corrected on the plan set.
1) The proposed gas line after the T is undersized (3/4") for the proposed water heater (199k Btu per G2413.1-3). Please revise the size to adhere to the fuel gas line provisions in Table G2413.4(1) (Metallic Pipe), of the 2024 IRC
2) Please provide the manufacturer's specifications of the Tankless Water Heater to ensure code compliance.
3) Specify the pipe material of all pipes, existing or new.
11/02/2026 PDSD Application Completeness Express REVIEW COMPLETED