Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL FENCE/WALL v.1
Permit Number - TC-RES-1026-05769
Review Name: RESIDENTIAL FENCE/WALL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/03/2026 | Light Residential Building Review (OIP) | NOT REQUIRED | |||
| 10/19/2026 | Residential Zoning | NOT REQUIRED | Zoning approval is not required for fences 6 feet or less in heigh. | ||
| 11/03/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/28/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-RES-1026-05769 Location: 2530 S CALLE CORDOVA Review Date: 10/28/2026 A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal. Residential Engineering Comments: 1. Floodplain Use Permit: The proposed fence replacement in the City of Tucson recognized Flood Hazard Area now has a floodplain use permit (TE-FPU-1026-00436) that must be completed to progress with construction of this Residential Wall/Fence permit. 2. Flood Compliance: To maintain compliance with City of Tucson Floodplain Standards, the proposed fence must provide 6” of clearance above natural grade OR an approved form of flood venting to allow water to flow unobstructed. Please update and resubmit the drawings and add a note to Site Plan [1543899 - Elevation Plan (engine)] and Construction Plans [CONS-1543899 Site Plan (1)-2530-CALLE CORDOVA-] showing the 6” clearance or flood venting. 3. Update Property Dimensions: Site dimensions as shown on the Site Plan do not match the county recorded dimensions. Please update to include those accurate and recorded dimensions. Current fence dimensions will need to be updated as well, as they currently exceed that available real property. Reference: https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=14070 4. Missing Easement: Update Site Plan to show 20’ drainageway, 10’ alley, and 6’ alley easement per the recorded plat (see reference/link in previous comment.) Easements must be shown on plans, and the proposed (and existing) fence must remain out of the easement. 5. Resubmittal: Please resubmit the requested changes for the Site Plan [1543899 - Elevation Plan (engine)] and Construction Plans [CONS-1543899 Site Plan (1)-2530-CALLE CORDOVA-] to both permits TC-RES-1026-05769 and TE-FPU-1026-00436 at TDC-Online.tucsonaz.gov for review and approval from Residential Engineering. If you have any questions or concerns, please contact Dylan Molina. Dylan.Molina@tucsonaz.gov |
||
| 10/19/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |