Permit Number: TC-RES-1026-05722
Parcel: 11623102B

Address:
932 W 21ST ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1026-05722
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/21/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/20/2026 Residential Building REQUIRES RESUBMIT TC-RES-1026-05722
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review includes architectural, plumbing, mechanical, energy conservation and electrical compliance with the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2024 IRC with amendments and building ordinances for all dwellings.

Provide a separate response letter addressing each comment with location of change on the plans.

GENERAL COMMENTS:
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Building-Codes

1. Plans submitted for a newly constructed one- or two-family dwelling after July 1, 2009, require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549 and 2024 IRC appendix NB. Show the clear solar-ready zone on a roof or framing plan with a minimum 1-1/4” capped roof penetration routed to the electrical service panel. Label a double breaker space “For Future Solar Electric” on the panel schedule opposite end from the main/supply side. Relocate the breaker space location.
2. Plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, require gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. The ordinance revision now requires a gray drain line discharge from one fixture for a one-story dwelling. Additional gray fixture drains are optional. Show a dual clothes washer standpipe with a black connection and a gray line plumbed to an exterior wall above grade when feasible, or a bathing fixture drain looped 3’ beyond an exterior wall below grade before connection to the building drain. Use the appropriate detail at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations

PLANS:

1. Remove all outdated code references, R106.1.1. Incorrect entries were found on sheets 3, 4 & 5.
2. Provide a minimum 6 mil polyethylene vapor retarder with joints lapped not less than 6 inches between the concrete floor slab and the base course or the prepared subgrade where a base course does not exist, R506.3.3.

MECHANICAL PLANS:

1. Remove the email instructions for air leakage results, R106.1.1. The city uses the submittal process for document filing.
2. Identify the device model number providing an adjustable setting and note the minimum continuous setting for providing whole-house mechanical ventilation, R303.4; N1103.6 & M1505.4.

ELECTRICAL PLANS:

1. Specify the Electric Vehicle NEMA 14-50R receptacle at a parking area, N1104.2.1.
2. Show a surge-protective device (SPD) as an integral part of or placed immediately adjacent to the service equipment, E3606.5.
3. Remove receptacles from the exterior face of island cabinets where below the countertop. Either provide a vertical assembly listed for countertop (work surface) mounting, or a raceway terminated within the cabinet for future assembly installation, E3901.4.2.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Energy Certificate: (Mandatory) place inside near an indoor furnace or utility room, IECC R401.3. Update note #3 on sheet 5.

Please contact the plans reviewer if you have any questions:
Kenneth.VanKarsen@tucsonaz.gov
City of Tucson Residential Building Safety
10/20/2026 Residential Engineering REQUIRES RESUBMIT Permit Activity Number: TC-RES-1026-05722 (1st Review)
Project: SFR
Location 932 W 21ST ST
Review Date: 10/20/2026
Reviewer: John Mounsey – Engineering Associate - Residential Engineering
Reviewer Contact: John.mounsey@tucsonaz.gov

Residential Engineering comments are as follows:
1. Per the City of Tucson Inclusive Home Ordinance 10463: all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in 2017 ICC A117.1 Sections 402-404 of the Accessibility Standards. See also TSM 7-01.4.3 for specifications, including the minimum 4ft-width, slope and permissible composition materials. Gravel is not an acceptable surface for an accessible route.
2. On the site plan please include utilities including the gas and sewer lines.
10/21/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL
FROM: Roxanne Johnston, Planner
PROJECT: TC-RES-1026-05722
932 W 21st St., Tucson AZ 85745
SFR (1st Review)

TRANSMITTAL DATE: 10/21/2026
This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.
RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.
1. Provide a landscape plan. Landscape has been required for all new residential development as of January of this year per Ordinance No. 12219. To see the landscape requirements, visit https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code . The landscape plan is to be added directly to the site plan and does not require a landscape architect. Please read the instructions through to the final page.
2. Recalculate lot coverage by omitting the square footage of the porches. Per Unified Development Code 6.4.3.C.1.a., porches are excluded from lot coverage.

3. For the next submittal, please include the following:
a. Revised site plan containing the landscape plan
b. Construction plans
c. Comment Response Letter addressing all staff comments.
3. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.
If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov
10/19/2026 PDSD Application Completeness Express REVIEW COMPLETED