Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1026-05640
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/23/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/19/2026 Residential Building REQUIRES RESUBMIT TC-RES-1026-05640
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review includes architectural, plumbing, mechanical, energy conservation and electrical compliance with the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2024 IRC with amendments and building ordinances for all dwellings.

Provide a separate response letter addressing each comment with location of change on the plans.

GENERAL COMMENTS:
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Building-Codes

1. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc.
2. Plans submitted for a newly constructed one- or two-family dwelling after July 1, 2009, require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549 and 2024 IRC appendix NB. Show the clear solar-ready zone on a roof or framing plan with a minimum 1-1/4” capped roof penetration routed to the electrical service panel. Label a double breaker space “For Future Solar Electric” on the panel schedule opposite end from the main/supply side.
3. Plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, require gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. The ordinance revision now requires a gray drain line discharge from one fixture for a one-story dwelling. Additional gray fixture drains are optional. Show a dual clothes washer standpipe with a black connection and a gray line plumbed to an exterior wall above grade when feasible, or a bathing fixture drain looped 3’ beyond an exterior wall below grade before connection to the building drain. Use the appropriate detail at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations
4. Show compliance with the Electric Vehicle Supply Equipment Ordinance adopted by the City of Tucson Ordinance #11844 on 6/22/2021 and 2024 IRC appendix NE. Include a 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle for charging an electric vehicle at a proposed parking space.

SITE PLAN:

1. Show a connection to the existing sewer HCS as each property requires a single connection, R106.1.1.
2. Each dwelling unit (with kitchen) requires a separate Pima County assigned street address, R308. Obtain a new address for the ADU at: https://www.pima.gov/addressing Notate each dwelling address on the site plan.

PLANS:

1. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1.

SECTIONS - DETAILS:

1. Provide the detail for a one-hour fire-resistive framed construction separating dwellings in compliance with IBC Table 721.1(2) which is referenced at keynote #23 on sheet A0.2.
2. Provide the attic space ventilation calculation and show the attic vent opening sizes using 1 to 150 of attic area in compliance with R806.2. Provide appropriate upper and lower space vents when applying the reduced area calculation.

MECHANICAL PLANS:

1. Provide demand calculations in accordance with Manual J standards, M1401.3, M1601.1.
2. Identify the device model number providing an adjustable setting and note the minimum continuous setting for providing whole-house mechanical ventilation, R303.4; N1103.6 & M1505.4.
3. Show a dryer vent size and location for venting to exterior, M1501.
4. Show bathroom (without a window) exhaust fan locations ducted to the exterior, R325.2 and M1505.2.
5. Provide makeup air of not less than 100 square inches where a clothes dryer is placed in a closet, M1502.6.1.

PLUMBING PLANS:

1. Show an individual accessible water supply shut off for each dwelling unit, P2903.9.1. Remove the water line passing through the separating wall.
2. Show the water heater rating/capacity for consistence with the electrical circuit size, R106.1.1.

ELECTRICAL PLANS:

1. Show the Electric Vehicle Supply Equipment 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle and label the circuit “EV Ready” and locate the receptacle at a parking area, N1104.2.1. Include the Electric Vehicle load entry (typically 7680 watts) in the electrical load calculations (continuous demand) like the HVAC entry, N1104.2.2.
2. Specify the Electric Vehicle NEMA 14-50R receptacle at a parking area, N1104.2.1.
3. Provide a panel schedule showing appropriate circuit numbers consistent with the plan layout, E3404.13 & E3706.2.
4. Show receptacle outlets at each kitchen counter space wider than 12” with no point along the wall line more than 24” from a receptacle outlet, E3901.4.1. Show receptacles within 2’ of counter edges or corners and no more than 4’ apart.
5. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3.
6. Show a surge-protective device (SPD) as an integral part of or placed immediately adjacent to the service equipment, E3606.5.
7. Provide GFCI protection for appliance receptacle outlets, E3902.12 & 14. Include the Dishwasher, Electric range, Clothes dryer, Microwave oven and HVAC equipment.

Please contact the plans reviewer if you have any questions:
Kenneth.VanKarsen@tucsonaz.gov
City of Tucson Residential Building Safety
10/14/2026 Residential Engineering REQUIRES RESUBMIT Site Engineering Review

TC-RES-1026-05640
6509 S CRAYCROFT RD
Date of Transmittal: 10/14/2026
Description: new SFR with attached ADU

City of Tucson Code:
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes

City of Tucson Inclusive Home Ordinance 10463
https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf

Site Engineering comments are as follows:

1. Per the City of Tucson Inclusive Home Ordinance 10463: all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance for each unit. Ensure the route meets accessibility standards described in Sections 402-404 of the ICC A117 Accessibility Standards. Specifications also include maintaining a minimum 4ft-width. Be sure to draw, dimension, and label the route and define its composition.
2. Please correct the spelling of “Vicinity” on the next submittal.
3. The Legal Description of the lot on the cover sheet is incorrect. Please see Bk 11, Pg 1, Littletown No. 2 for the correct information. The correct Legal description is, “LITTLETOWN NO 2 LOTS 19 & 20 BLK 3.” APN: 140-38-150A
4. Additional comments may be forthcoming depending on the content of files submitted for subsequent review cycles.

*Please submit revised drawings along with a detailed response letter stating how each resubmittal comment has been addressed*

To re-submit, visit the Tucson Development Center Online at:
https://cityoftucsonaz-energovweb.tylerhost.net/apps/selfservice#/home

Engineering Associate: Ryan Insalaco
ryan.insalaco@tucsonaz.gov
10/23/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Erick Bieber
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-1026-05640– Residential Building
6509 S Craycroft Rd, Tucson, AZ 85756
New Dwelling Permit (1st Review)

TRANSMITTAL DATE: October 23rd, 2026

This site is located in the R-1 zone (UDC 4.7.8). Middle Housing is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .8, .9, & .11-.14.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. (Comment) Per UDC 4.9.7.B.12, front yards are permitted one driveway no more than 20’ in width and up to 400 square feet of additional vehicular use area. The driveway shown is 28’ wide.

2. (Comment) Aerial imagery shows a large canopy structure in the middle of the property. Please clarify whether this structure will remain on site or whether it will be demolished.

3. (Comment) Per the subdivision plat map, there appears to be a 10’ utility easement along the east property line. Please show the easement on the site plan.

4. (Comment) Per UDC 7.6.8, all new residential developments consisting of 1-4 units require basic native, drought-resistant landscaping to be added to the site plan.
a. Per UDC 7.6.8.A.1, one canopy tree is required for every 1,000sqft of GFA of the development project. This project will need 3 canopy trees. 50% of required canopy trees must be placed in the front yard.
b. Per UDC 7.6.8.A.2, 5 square feet of vegetative groundcover is required in the front yard for every foot of front yard property line width, minus any curb cut width. Calculate required groundcover using the following equation:
(X Linear feet of Street Frontage) - (Y Curb cut width) x (5 Foot Depth) = Z Square Feet of vegetative groundcover
c. Provide plant species for both the vegetative groundcover and canopy trees to ensure that they are ADWR Low Water Use approved plant species. See the link below to learn more about approved plant species.
d. Existing landscaping may be used to meet landscaping standards but must be indicated and labeled on the site plan.
To learn more about the new residential landscaping code, please visit the following link: https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code
To learn more about the new residential landscaping code, please visit the following link: https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code

For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov
10/14/2026 PDSD Application Completeness Express REVIEW COMPLETED