Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-1026-05638
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/09/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/09/2026 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | If you have questions regarding this Review, please contact PDSD-Permits@tucsonaz.gov Please resubmit addressing the following comments: 1) Modifications to the gas system require the submission of a gas pipeline template (or equivalent) identifying the pipe material, pipe size, and developed length of each section to determine code compliance, G2401.1, G2413.1, R301.1. 2) Special callout for portion being replaced (replace/repair) 3) Provide appliance demands. G2413.4.1, Table G2413.4(1). 4) Include the address, including unit number. Note: Indicate any transitions in material from one section to another (e.g. underground poly to above-ground black iron). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_handout_2018_irc_2019.2.4.pdf https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_piping_template_060324.pdf https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_piping_sample_060324.pdf |
||
| 10/09/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |