Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1026-05594
Parcel: 126210040

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-1026-05594
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/13/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/13/2026 Light Residential Building Review (OIP) - Standard REQUIRES RESUBMIT If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov
Please resubmit addressing the following comments:
1) 4 Panel schedules are on the plan set; however, the 3-line diagram does not show location of Sub A-2. Show the interconnection of A-2.
2) The SES Main Panel shows a PV Interconnection. Show PV interconnection and mark as existing to evaluate interconnection compliance with NEC 705.
3) Provide load calculations for all sub panels and show feeders adequately supply loads in each panel. 215.2
4) For future reference, this project or projects with a similar scope of work may be eligible for review under a Residential Trade Permit.
10/13/2026 PDSD Application Completeness Express REVIEW COMPLETED