Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1026-05586
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/22/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/13/2026 Addressing Validation REQUIRES RESUBMIT If you have questions regarding the addressing validation, please contact our team at PDSD-Permits@tucsonaz.gov. Please resubmit site plan with full address indicating the SPECIFIC BUILDING NUMBER AND UNIT NUMBER, after other reviews are complete. Here are the Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf
10/13/2026 Residential Building REQUIRES RESUBMIT TC-RES-1026-05586
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2024 IRC with amendments and building ordinances for all dwellings.

An impact fee payment is required for an ADU or second dwelling at the time of permit payment.

GENERAL COMMENTS:
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Building-Codes

1. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc.

SITE PLAN:

1. Show the utility meters and lines from the utility source to the building, R106.1.1. Note the electrical line as underground unless overhead is approved by TEP. https://www.tep.com/construction-applications/#apply Identify the utility lines requiring upgrade or replacement.
2. Each dwelling building requires a street address and a separate permit, R319. Show Pima County assigned unit numbers at each dwelling on the site plan

PLANS:

1. Notate a cool (white) roof finish (greater than 60 SRI) as required by the ADU provisions.
2. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. The threshold condition may be located at the garage/dwelling doorway or at an exterior hinged door.
3. Provide a minimum 6 mil polyethylene vapor retarder with joints lapped not less than 6 inches between the concrete floor slab and the base course or the prepared subgrade where a base course does not exist, R506.3.3.

SECTIONS - DETAILS:

1. Show one-hour fire-resistive framed construction separating dwellings in compliance with IBC Table 721.1(2). Update detail #7 on sheet 3-S101.
2. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Clarify the ceiling/roof insulation detail showing the air-impermeable rigid insulation material adhered to either side of the roof sheathing and the batt insulation in contact with the roof material.

MECHANICAL PLANS:

1. Show the HVAC system size for the building demand in accordance with M1401.3, M1601.1.
2. Provide demand calculations in accordance with Manual J standards, M1401.3, M1601.1.
3. Identify the device model number providing an adjustable setting and note the minimum continuous setting for providing whole-house mechanical ventilation, R303.4; N1103.6 & M1505.4.
4. Show a dryer vent size and location for venting to exterior, M1501.
5. Provide makeup air of not less than 100 square inches where a clothes dryer is placed in a closet, M1502.6.1.
6. Show bathroom (without a window) exhaust fan locations ducted to the exterior, R325.2 and M1505.2.

PLUMBING PLANS:

1. Show the water heater rating/capacity for consistence with the electrical circuit size, R106.1.1.

ELECTRICAL PLANS:

1. TEP may require the service panel for the property at the closest building to the service transformer. A service line change or a new meter location must be coordinated with TEP for approval. Show an underground feeder from a metered service panel to the more distant dwelling.
2. Update the Riser Diagram showing a service panel for both the primary and ADU dwellings, E3403. Show the ADU feeder size and appropriate breaker requirement, E3602.1 & E3603.1.
3. Show a second 2O AMP small appliance circuit at the kitchen countertop, E3703.2 and E3901.3.
4. Provide GFCI protection for appliance receptacle outlets, E3902.12 & 14. Include the Dishwasher, Electric range, Clothes dryer, Microwave oven and HVAC equipment.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Energy Certificate: (Mandatory) place inside near an indoor furnace or utility room, IECC R401.3. Add notation to plans.
2. Specify high-efficacy luminaires with an efficacy not less than 45 lumens per watt or lamps with efficacy not less than 65 lumens per watt (LED devices), IECC R404.1. Remove the percentage limit from note #1.

If you have any questions, please contact:
Kenneth.VanKarsen@tucsonaz.gov
City of Tucson Residential Building Safety
10/19/2026 Residential Engineering REQUIRES RESUBMIT Site Engineering Review

TC-RES-1026-05586
1928 E COPPER ST
Date of Transmittal: 10/19/2026
Description: Duplex Casita

City of Tucson Code:
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes

City of Tucson Inclusive Home Ordinance 10463
https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf

Site Engineering comments are as follows:

1. Per the City of Tucson Inclusive Home Ordinance 10463: all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance for each unit. Ensure the route meets accessibility standards described in Sections 402-404 of the ICC A117 Accessibility Standards. Specifications also include maintaining a minimum 4ft-width. Be sure to draw, dimension, and label the route and define its composition.
2. Additional comments may be forthcoming depending on the content of files submitted for subsequent review cycles.

*Please submit revised drawings along with a detailed response letter stating how each resubmittal comment has been addressed*

To re-submit, visit the Tucson Development Center Online at:
https://cityoftucsonaz-energovweb.tylerhost.net/apps/selfservice#/home

Engineering Associate: Ryan Insalaco
ryan.insalaco@tucsonaz.gov
10/22/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Drew Szentesy
Planner
PROJECT: 1928 E COPPER ST Unit:BLDG 2 UNIT 2101 TUCSON, AZ 85719
New Duplex

TRANSMITTAL DATE: 10/22/2026

This site is located within the R-2 Zone (UDC 4.7.9). A middle housing duplex is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .8, .9, & .11-.14.
RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. You need to include organic vegetative groundcover for any new dwellings according to the Tucson Unified Development Code 7.6.8. Required square footage of vegetative groundcover (shrubs may be substituted providing they cover the required square footage) is 200 square feet ((60ft frontage – 20ft curb cut) X5). Please refer to this link for landscape requirements: https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code
2. List the common names for the required groundcover/shrubs and the preferred watering method.
3. Please include three trees on this property. Over 3000 square feet of dwelling space requires 3 trees per our residential landscape code 7.6.8: https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code
Existing of 4” in diameter trees may count toward this requirement if their root systems are protected during construction and the mature tree canopy will not be compromised by proposed structures.
4. Per the City of Tucson Inclusive Home Ordinance 10463: all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the Accessibility Standards. See also TSM 7-01.4.3 for specifications, including the minimum 4ft-width, slope and permissible composition materials. Gravel is not an acceptable surface for an accessible route.
5. Please adjust lot coverage calculations to ensure that the new vehicular use area is included.


The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code
For questions regarding Zoning comments, please contact me at: Drew.Szentesy@tucsonaz.gov
10/13/2026 PDSD Application Completeness Express REVIEW COMPLETED