Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-1026-05557
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/12/2026 | Residential Engineering | APPROVED | RE: comments in TE-FPU-1026-00420 | ||
| 10/09/2026 | Residential Zoning | APPROVED | |||
| 10/14/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/14/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-1026-05557 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review includes architectural, plumbing, mechanical, energy conservation and electrical compliance with the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 code compliance. Place the current reference code on sheet C-1.0. Provide a separate response letter addressing each comment with location of change on the plans. SITE PLAN: 1. Show the utility meters and lines from the utility source to the proposed construction, R106.1.1. Identify the utility lines requiring upgrade or replacement for supplying the demand of the proposed construction. 2. Each dwelling unit (with kitchen) requires a separate Pima County assigned street address, R308. Obtain a new address at: https://www.pima.gov/addressing Notate each dwelling address on the site plan. PLANS: 1. Show compliance with R304 providing habitable rooms with not less than 70SF and horizontal dimensions not less than 7’. Show the dimensions of the proposed bedroom. 2. Show the “R” values of wall and ceiling insulation at the new conditioned space, N1102.1. MECHANICAL PLANS: 1. Show the mini-split size for the space demand in accordance with M1401.3, M1601.1. Include each habitable room, R325.8. ELECTRICAL PLANS: 1. Show a smoke alarm in the bedroom and outside the doorway in the immediate vicinity with an electrical circuit, R314.3. 2. Show the mini-split circuit size for serving the load, E3702.12. 3. Show (new wall) receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2. 4. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. 5. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 10/09/2026 | Design Review - Standard | REVIEW COMPLETED | No impact from right-of-way, design review not required. | ||
| 10/08/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |