Permit Number: TC-RES-1026-05497
Parcel: 136383270

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-1026-05497
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/12/2026 Residential Zoning APPROVED
10/07/2026 Residential Engineering NOT REQUIRED
10/12/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/12/2026 Residential Building - Standard REQUIRES RESUBMIT Please review the comments below and re submit.

1.M1502.6.1 Closet installation: where a closet is designed for the installation of a clothes dryer, makeup air shall be provided in accordance with the dryer manufacturer's installation instructions or with openings totaling not less than 100 square inches.
Provide makeup air of not less than 100 square inches where a clothes dryer is placed in a closet, M1502.6.1.

2. P2903.6 Existing piping used for grounding: existing metallic water service piping used for electrical grounding shall not be replaced with nonmetallic pipe or tubing until other approved means of grounding is provided.

3.An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5.

4. Show a smoke alarm in the bedroom and outside the doorway in the immediate vicinity with an electrical circuit, R314.3.

5. Show compliance with the energy code requirements, N1102.1.
10/05/2026 PDSD Application Completeness Express REVIEW COMPLETED