Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-1025-05319
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/26/2026 | Residential Engineering | APPROVED | |||
| 03/11/2026 | Residential Zoning | APPROVED | |||
| 03/11/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/26/2026 | Residential Building | REQUIRES RESUBMIT | TC-RES-1025-05319 2nd PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. Provide a separate response letter addressing each comment with location of change on the plans. PLANS: 1. Notate a cool (white) roof finish (greater than 60 SRI) as required by the ADU provisions. 2. Provide a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)). Sheet 4 shows 2 x 12 joists spanning the 30’ wide building. Change the joist type or add a load bearing wall between the dwelling and storage room with a foundation. ELECTRICAL PLANS: 1. Smoke alarms are required outside each separate sleeping area, R314.3.2. Show a smoke alarm outside the bedroom doorway. 2. The dishwasher with GFCI readily accessible protection typically from an upstream device, E3902.9 & 10. OUTDOOR LIGHTING CODE 1. Update the Outdoor Lighting Calculation with an approved property area entry, OLC 401. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 02/24/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |