Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1025-05289
Parcel: 136082160

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADU v.2

Permit Number - TC-RES-1025-05289
Review Name: RESIDENTIAL ADU v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/14/2026 Residential Zoning APPROVED Approved with comments: Per UDC Article 6.6.3.B.4, the roof (for new ADUs) must be
developed with a high albedo level (>60 SRI) or other cool roof technology per the ICC
Green Construction Code. The asphalt shingles used in this project must meet these requirements.
01/14/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/07/2026 Addressing Validation REQUIRES RESUBMIT There are now two units linked to this parcel. However, a change of address request must still be submitted through the sub records of this permit to add the ADU unit number to this permit. Please resubmit construction plans with full address and unit number on each page.

Instructions can be found here for change of address request: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf

For questions: PDSD-Residential@tucsonaz.gov
01/08/2026 Residential Building REQUIRES RESUBMIT TC-RES-1025-05289 2nd
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The 2024 IRC is in effect for first permit submittals after Jan 1, 2026.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

SITE PLAN:

1. Show the location of water and electric line connections, R106.1.1. Include keynotes 2 & 8 on the plan.

SECTIONS - DETAILS:

1. Individual dwelling units require separation with a 1-hour fire-resistance rated assembly without openings, R302.3. Provide a detail or notation showing compliance with 703.3 of the 2018 IBC. Include any fill-in of existing window or door openings.
2. Show the door from a garage to dwelling with a 20-minute fire rating (or 1-3/8” solid core) with self-closing and self-latching provision, R302.5.1.

MECHANICAL PLANS:

1. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Show the minimum airflow rate setting and location of the device requiring this adjustable setting. A one-bedroom dwelling under 1501 SF requires a 30 CFM continuous setting.

ELECTRICAL PLANS:

1. Show the location of Panel A, E3405.2.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. The simplified prescribed energy value for glazing is U=0.40, N1102.1. Correct the “U-75” notation at the Mechanical Plan.

OUTDOOR LIGHTING CODE

1. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. Remove the “optional” notation from sheet 5.

If you have any questions, please contact:
Ken Van Karsen
520 837-4912
City of Tucson Residential Building Safety

----------------------
01/07/2026 Residential Engineering REQUIRES RESUBMIT Permit: TC-RES-1025-05289
Location: 9402 E 29TH ST
Review Date: 1/7/2026
Site Engineering Comments:
1. Please draw and dimension 15-foot utility easement on site plan. Per final plat it is shown on the western boundary of the property.
2. Per the City of Tucson Inclusive Home Design Ordinance (https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards (https://www.access-board.gov/ada/chapter/ch04/). See TSM 7-01.4.3 for specifications.
Corey Hines
Corey.Hines@TucsonAZ.gov
01/07/2026 PDSD Application Completeness Express REVIEW COMPLETED