Permit Number: TC-RES-1025-05252
Parcel: 123172890

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1025-05252
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/21/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/31/2025 Addressing Validation REQUIRES RESUBMIT This permit is for the new SFR at 1725 N Highland Ave. Please submit a separate permit for the conversion of the existing duplex into ADUs.
11/04/2025 Residential Building REQUIRES RESUBMIT TC-RES-1025-05252
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. The 2024 IRC will be in effect Jan 1, 2026.

Permits are issued for the building address rather than for the parcel. This permit will progress for the new SFR but the alterations for 1715 and 1717 N Highland Ave requires submittal of a different permit application. These buildings will have different inspection schedules from the SFR.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

GENERAL COMMENTS :

1. A permit requires the correct application type. Request an addition/alteration permit for the duplex.
2. Plans submitted for a newly constructed one- or two-family dwelling after July 1, 2009 require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549. Label a double breaker space for future Photo Voltaic on the panel schedule opposite end from the main/supply side, T103.9

SITE PLAN:

1. Show the location of the electric panels (keynote #6) consistent with the equipment locations on sheet E2.0, R106.1.1.
2. Each dwelling unit should have an individual 3-foot clear space (including the roof projections) known as the fire separation distance for reducing fire spread to nearby buildings. Portions of buildings placed in a fire separation distance require one-hour fire-resistive construction in compliance with IBC Table 721.1(2). Consider a six-foot separation between roof edges or show fire spread rated material details.

PLANS:

1. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. Include the threshold condition at the vehicle doorway or an exterior hinged door when the garage is used for the accessible route.

SECTIONS - DETAILS:

1. Show one-hour fire-resistive framed construction of the SFR wall placed within the imaginary property line between dwelling in compliance with IBC Table 721.1(2). The line should be placed 3 feet away from the existing dwelling roof projection unless adding fire rated materials to the existing roof overhang underside.
2. A roof projection of each dwelling may not extend closer than 24” to the imaginary property line between dwellings. The roof overhangs of adjacent dwellings may not be closer than four feet from each other. Any part of a roof projection extending into the 3-foot fire separation distance from the imaginary property line between dwellings requires not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended).
3. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Clarify the ceiling/roof insulation details showing the air-impermeable rigid insulation material adhered to either side of the roof sheathing along with the batt insulation.

MECHANICAL PLANS:

1. Provide mechanical plans for review.
2. Show the HVAC system size for the building demand in accordance with M1401.3, M1601.1.
3. Provide demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. .
4. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Identify the device model number providing an adjustable setting and note the minimum continuous setting. A two or three-bedroom dwelling under 1501 SF requires a 45 CFM continuous setting.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans.

Please contact the plans reviewer if you have any questions:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
11/17/2025 Residential Engineering REQUIRES RESUBMIT Permit: TC-RES-1025-05252
Location: 1725 N HIGHLAND AV
Review Date: 11/17/2025
A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal.
Residential Engineering Comments:
1. The proposed primary access for the new dwelling is located on Chauncey Ln. Please provide a width dimension for Chauncey Ln.
2. Additional comments may be forthcoming.
If you have any questions or concerns, please contact Dylan Molina.
Dylan.Molina@tucsonaz.gov
11/06/2025 Residential Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-1025-05252
1725 N HIGHLAND AV. – R-2
New SFR and conversion of existing duplex to two attached ADUs (1st Review)

TRANSMITTAL DATE: November 6, 2025

COMMENTS: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) with an accessory dwelling unit (ADU) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards .9.7.B.6, 8, & 9 and 6.6.3.

1. Provide a dimension from the centerline of both streets to the face of curb and from face of curb to the applicable property line.

2. Provide property dimensions on the plot plan.

3. Provide the width of Chauncey Ln. on the plot plan.

4. Per the City of Tucson Inclusive Home Design Ordinance (https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf), all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards (https://www.access-board.gov/ada/chapter/ch04/). See TSM 7-01.4.3 for specifications, including slope and composition materials

5. Per UDC Article 6.6.3.C Detached accessory buildings, including accessory dwelling units, are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line. A Board of Adjustment for Variance is required for this permit to be approved as shown.

6. As Chauncey Ln is a named alley it is considered a street and street perimeter yard setbacks are required. Per UDC Article 6.4.5.C.1.b the setback is 10’, proposed is 9’-10”. The reduced setback can be processed with the Board of Adjustment above.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
11/21/2025 Fire New Construction Standard REVIEW COMPLETED
10/31/2025 PDSD Application Completeness Express REVIEW COMPLETED