Permit Number: TC-RES-1025-05170
Parcel: 134050490

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.2

Permit Number - TC-RES-1025-05170
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/30/2025 Residential Building - Standard APPROVED
12/30/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/19/2025 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston
Planner

PROJECT: TC-RES-1025-05170
9417 E El Cajon Dr., Tucson, AZ 85710
Shed (2nd Review)

TRANSMITTAL DATE: 12/19/2025

This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. The height of the shed walls are incorrect. Per UDC 6.4.4.A, wall height is measured from design grade to the top of the wall to determine side and rear perimeter setbacks. Please revise the building elevations on Sheet A1.0 and the Elevation block on Sheet C1.0 .

2. The west side perimeter setback shown on Sheet C1.0 is 5’. Per UDC Table 6.3-2.A, the perimeter side setback requirement for the R-1 zone as of the current UDC is 6’ or 2/3 the height of the exterior wall, whichever is greater. However, an option for allowing the 5’ setback is available as the Mayor and City Council recently approved code amendments that would allow for the 5’ setback. This would not go into effect until Jan. 16th, 2026. If you do not want to wait that long than options ‘a.’ and ‘b.’, below are could be more time efficient. Option ‘c’, below, takes a minimum of 6 weeks to get approval from the time the application is taken in as it involves public noticing.

a. Either move the structure out of the 6’ perimeter setback,
b. Obtain a Neighbor Waiver from the owner located at 605 S Santa Ana Place, or
c. Apply for a Design Development Option (DDO) if a Neighbor Waiver cannot be obtained.

The Neighbor Waiver must be directly applied to the site plan and read something similar to the following: My name is _______ and I am the owner at 605 S. Santa Ana Place. I have reviewed the site plan for the shed and have no objection to the shed being located 5’ from the rear property line. Signed: __________ Dated:_________.

To submit an application for a DDO, please use the link and follow the instructions below:
www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/boards-committees-commissions/drb/012425/ddo-24-81-application-packet.pdf Submit a DDO application under the Zoning Modification sub-record that you will create - for instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf For additional questions regarding DDOs, contact Mark Castro at Mark.Castro@tucsonaz.gov

3. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
12/10/2025 PDSD Application Completeness Express REVIEW COMPLETED