Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.2
Permit Number - TC-RES-1025-05112
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/21/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/21/2025 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | Please resubmit addressing the following comments: 1) Demonstrate on plans where the Furnace is being supplied, if applicable. 2)The pipe suppling all branches (prior to T toward Range) is undersized for the given length (46') and appliance demand. Minimum pipe size should be 1" before the tee. Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) (Polyethylene Plastic Pipe), or Manufacturer’s sizing requirements. For any questions, please email: PDSD-Residential@tucsonaz.gov |
||
| 10/21/2025 | PDSD Application Completeness Express | REVIEW COMPLETED | Owner name on OBA does not match owner information registered with Pima County. Please resubmit OBA with property owner name. The permit application must also list the same owner information. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf |