Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1025-05111
Parcel: 112012820

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-1025-05111
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/06/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/06/2025 Residential Building - Standard REQUIRES RESUBMIT Please review the comments below and resubmit with the info required for a permit.

1. Framed exterior walls of enclosed roof structures require continuous concrete footings of minimum 12” width and 12” below the undisturbed ground surface, R403.1.
2. Provide the dimensions of all structures on site, the distances from property lines to structures, square footage calculations
3.Label all rooms and spaces. Show floor plan for all rooms adjoining additions, R106.1.1.
4.Identify ceiling heights in all areas. Note average height at sloped ceiling areas, R305.1.
5.Show location, size, and operable portion of all doors and windows, R106.1.1.
6.Specify the size and spacing of rafters, R802.4.
7. When the roof pitch is less than 3:12, design structural members that support rafters and joists as beams (such as ridges, hips, and valleys), R802.4.4.
8.Provide a panel schedule: panel size, circuit numbers, ampacity, and wire sizes, for any electrical work. E3404.11, E3706.2.
10/31/2025 Residential Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-1025-05111
3020 E WEYMOUTH ST. – R-3
Add arizona room to back of home (1st Review)

TRANSMITTAL DATE: October 31, 2025

COMMENTS: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

This site is located in the R-3 zone (UDC 4.7.12). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6.

1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
10/23/2025 PDSD Application Completeness Express REVIEW COMPLETED