Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1025-05099
Parcel: 133381660

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.3

Permit Number - TC-RES-1025-05099
Review Name: RESIDENTIAL ADD/ALT v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/26/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/08/2026 Addressing Validation REQUIRES RESUBMIT The address on the 1st page of the construction documents is 10681 E CAMINO QUINCE however the address listed on the permit is 10682 E CAMINO QUINCE. Once this review is complete, please resubmit the construction plans and make sure the address on every page matches the address listed on the permit.

Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf

For questions: PDSD-Residential@tucsonaz.gov
01/26/2026 Residential Building - Standard REQUIRES RESUBMIT TC-RES-1025-05099 3rd
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections.

Note the 2018 IRC reference on the plans.

Provide a response letter addressing each comment with location of change on the plans.

Submit the letter in a separate file from the construction plan set file.

Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

SECTIONS - DETAILS:

1. Provide a proposed wall section detail for the proposed exterior framed (insulated) wall enclosing the vehicle door opening, R403.1.6. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground or 2” above a paved area, R703.7.2.1. A concrete stem wall base may be required for achieving the required separation.
2. Clarify the placement of ceiling/roof insulation with either a ventilated attic or sealed rafter cavity, R806. Identify the ventilation requirements and insulation types for complying with the condensation control issues.

PLUMBING PLANS:

1. Clarify the location of concrete cuts for placement of branch drainpipes P3005.4.1.

MECHANICAL PLANS:

1. Show a mini-split system or extended ducts for providing heating/cooling to the bedroom, M1401.3, M1601.1.

ELECTRICAL PLANS:

1. Show receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2.
2. Show a wall switch and light for each door entrance or exit, E3903.3.
3. Add a note to plans requiring an arc-fault circuit interrupter for all bedroom circuits, E3902.16.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Show compliance with the energy code requirements for placement of wall and ceiling insulation, N1102.1.

If you have any questions, please contact:
Kenneth.VanKarsen@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
----------------------
01/21/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-RES-1025-05099 – Residential Building – Garage Conversion to Bedroom/Bathroom
10682 E CAMINO QUINCE TUCSON, AZ 85748 (RX-1 Zoning)
Site Plan Review – 3rd Review

TRANSMITTAL DATE: January 21, 2026

This site is in the RX-1 Residence Zone (UDC 4.7.6). A single-family detached residence is permitted use in this zone (Table 4.8-7) per use specific standards 4.9.7.B.6, .8, & .9.

The City's Unified Development Code (UDC) (Section 1.4.1.C) establishes that before the City issues any approvals or permits; we must confirm that a site complies with UDC standards. Therefore, as part of permit reviews, we review a site's permit history and compare it to aerial photography to confirm that unpermitted work has not occurred. In many cases, this does mean that a homeowner must apply for permits for unpermitted work before we can approve any new work on that site.

Plan review for the above referenced Garage Conversion to Bedroom/Bathroom has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

1. COMMENT: Refer to previous Zoning reviewer comments for the following comments that were not addressed or partially addressed: https://cityoftucsonaz-energovweb.tylerhost.net/apps/selfservice#/permit/e813b26b-ba27-4d33-beed-cc383ead09df?tab=reviews :

Comment 1b: Lot dimensions are still not correct. Refer to https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=27058 for the subdivision plat.

Comment 1c: Incomplete. Draw and label 10’-0” wide utility easement. Additionally, there is no formal alley so this label can be removed.

Comment 1g: Incomplete. Provide dimension from carport to property line. While there is a label acknowledging there is a 22’-0” distance, a simple aerial imagery review indicates it is nearly on the property line and thus, why a neighbor waiver was offered but never included (even though the plans indicate it was).

Comment 2: Incomplete. Neighbor waiver not included.

(Neighbor Waiver Sample – Copy and Paste, exactly as shown, onto Site Plan):

My Name is __________________ and I am the owner of the property located at
________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan.

Signature: _______________________ Date:___________________________

Mi hombre es ________________ y yo soy el dueño de la propiedad ubicada en la _____________________. He revisado el plan y no tengo ninguna objeción a que estructura se encuentra o construye ____________ desde la línea de propiedad, como se muestra en el plan.

Firma: _________________________Fecha:__________________________

2. COMMENT: This parcel is in an Environmental Resource Zone (ERZ). Development within an ERZ is governed by UDC 5.7.

Per UDC Article 5.7.3, an Environmental Resource Report (ERR, in accordance with UDC Administrative Manual Article 2-03.5.0) and/or mitigation plan (in accordance with UDC 5.7.4.D) may be required if the development encroaches into the floodplain. See Site Engineering comments for more information and if any action is required.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

1. Corrected building permit

2. Provide a detailed response letter (clarification narrative) with your submittal that clearly shows how you have addressed all Zoning comments.

3. Resubmit ALL documents (all drawings in sheet index)

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code
01/08/2026 PDSD Application Completeness Express REVIEW COMPLETED