Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.2
Permit Number - TC-RES-1025-05099
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/31/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/18/2025 | Addressing Validation | REQUIRES RESUBMIT | Please include full property address on all pages of the site plans and resubmit after all other reviews are complete. You will not be able to submit while reviews are in progress. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf For questions: PDSD-Residential@tucsonaz.gov |
||
| 12/31/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-1025-05099 2nd PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections. Note the 2018 IRC reference on the plans. Provide construction plans with sheet numbering on each page in a single PDF file. Provide a response letter addressing each comment with location of change on the plans. Submit the letter in a separate file from the construction plan set file. Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits PLANS: 1. Show the functional name of each existing adjacent room, R106.1.1. Existing bedrooms with removed windows require code compliance for egress, R310. Include any alteration of door or window openings between existing and proposed rooms. SECTIONS - DETAILS: 1. Provide a proposed wall section detail at the enclosed garage door with (#4 rebar) reinforced 12” x 12” reinforced foundations for anchoring exterior framed (insulated) walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6. 2. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. A concrete stem may be required for achieving the required separation. 3. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Identify the ventilation requirements and insulation types for complying with the condensation control issues. PLUMBING PLANS: 1. Clarify the pipe diameter at the point of connection of the new cold-water line to existing service pipes. Existing water pipes may require replacement with larger sizes for controlling excessive water flow rates, P2903.7. A minimum 3/4” pipe is required for supplying water to the new bathroom group fixtures. 2. Show branch drainpipes in accordance with Table P3005.4.1. 3. Show plumbing vents (VTR) within acceptable distances from traps, P3105.1. MECHANICAL PLANS: 1. Show the HVAC system size accordance with M1401.3, M1601.1. ELECTRICAL PLANS: 1. Show a smoke alarm in the bedroom and outside the doorway in the immediate vicinity with an electrical circuit, R314.3. 2. Designate the circuit number at the location of each light fixture, receptacle, appliance, and equipment disconnect switch, R106.1.1. 3. Show receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2. 4. Show at least one wall switch controlled light or outlet in bathrooms, hallways, stairways, attached garages, outdoor entrances or exits and all habitable rooms, E3903.3. 5. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Show compliance with the energy code requirements for placement of wall and ceiling insulation, N1102.1. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 12/29/2025 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-1025-05099 10682 E Camino Quince, Tucson, AZ 85748 Garage Conversion to Bedroom/Bathroom (2nd Review) TRANSMITTAL DATE: 10/24/2025 This site is located in the RX-1 zone (UDC 4.7.6). A single-family residence is a permitted use in this zone (Table 4.8-1) subject to Use Specific Standards 4.9.7.B.6, .8, & .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Comment 1 was not fully addressed from the 10/30/25 Site Zoning review. The site plan depicted is missing information needed for a complete Site Zoning review and the review comment provided a link for the required information. Please visit the following link (https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example Add the following items to the site plan – links are provided for plat and lot information. These are some items from the required information: a. Correct Legal lot Description because that provided is for the entire subdivision: Rancho Del Este Lot 149 https://gis.pima.gov/maps/detail.cfm?&parcel=133381660 b. All correct lot dimensions https://maps-and-records.tucsonaz.gov/subdivisions/details/3213 c. 10’ utility easement along the south side of the lot per plat, not 5’ as listed. d. 30’ width between the center line of E. Camino Quince and the north lot line. e. 45’ width from the east property line to the centerline of S. Avenida Lot Reyes f. 35’ setback line per plat, along the east lot line. g. Distance from the carport located in the southern are of the lot to the lot line. h. Zoning of adjoining properties i. Engineer scale (for example, 1”=10’) j. Owner name(s) and address k. Distance between all exterior building walls and the property line l. Lot coverage per Unified Development Code (UDC) m. Elevations for the carport and existing garage. 2. The structure discussed in Comment 2 of the 10/30/25 Site Zoning Review is situated within the 30’ rear perimeter setback required by UDC Table 6.3-1. Because this structure sits within the setback, a Neighbor Waiver is required from the owner of 600 S Avenida Los Reyes. If able to obtain, this waiver must be applied directly to the site plan. It should read something similar to the following: I (or We) , (owner name) own 600 S. Avenida Los Reyes. I/we have reviewed the site plan for 10682 E Camino Quince and do not object to the carport being located _____ feet from my property. Signature:___________ Date:_____ If a neighbor waiver is not possible, a Design Development Option will be necessary. To submit an application for a DDO, please use the link and follow the instructions below: www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/boards-committees commissions/drb/012425/ddo-24-81-application-packet.pdf Submit a DDO application under the Zoning Modification sub-record that you will create - for instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf For questions regarding the DDO process, please contact Georgia Pennington at georgia.pennington@tucsonaz.gov 3. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 12/18/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |