Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1025-05095
Parcel: 133281150

Address:
8410 E BAKER ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.3

Permit Number - TC-RES-1025-05095
Review Name: RESIDENTIAL SIMPLE REVIEW v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/22/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/22/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT Please resubmit addressing the following comments:
1. Include pipe size, type (Black Iron, Poly, etc) and length. Show connections for gas meter to all gas appliances. Modifications to the gas system requires the submission of a gas pipeline template (or equivalent), G2401.1, G2413.1, R301.1
2. Modifications to the gas line and meter location may require that the existing system be enlarged to meet the total demand based on the new lengths, G2412.3, G2412.4.
See:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_handout_2018_irc_2019.2.4.pdf
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_piping_template_060324.pdf
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_piping_sample_060324.pdf
For any questions, please email: PDSD-Residential@tucsonaz.gov
10/21/2025 PDSD Application Completeness Express REVIEW COMPLETED