Review Date Reviewer's Name Type of Review Description Status Comments
10/21/2025 Light Residential Building Review (OIP) NOT REQUIRED
10/31/2025 Residential Engineering NOT REQUIRED
10/31/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/29/2025 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL
FROM: Roxanne Johnston
Planner
PROJECT: TC-RES-1025-05027
4762 S Calle Miura, Tucson, AZ 85714
Block Wall w/ Gates (1st Review)

TRANSMITTAL DATE: 10/29/2025

This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please correct plans, as noted in the comments below, along with a Response Letter indicating how all Site Zoning comments were addressed.

1. The current site plan is insufficient for Zoning to conduct a review. Zoning needs to verify that the wall will not be outside of the property lines. Please visit https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example and create a site plan according to the instructions . For a wall, please add the following:

a. The legal description: BRAVO 1 LOT 132
b. A scale (e.g. 1” = 10’-0”)
c. Owner name and address
d. North arrow
e. Dimensioned lot and perimeter setbacks – 20’ in the front, 6’ or 2/3 the height of the exterior wall to the north and west property lines, whichever is greater, and 10’ of 2/3 the height of the exterior wall to the east property line, whichever is greater.
f. The measurement from the center of Calle Miura to the curb(40’), and from the curb to the property line (10’) per the Bravo 1 Paving and Street Improvement plan: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-74-012 (I-74-012_012TIF)

g. Lot size (7,261 sq. ft). per the City of Tucson’s Unified Development Code (UDC) 6.4.3.B.
https://gis.pima.gov/maps/detail.cfm?&parcel=132161940
h. Zoning of lot (R-1) and zoning of abutting properties.

2. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

For questions regarding Zoning comments, please feel free to contact me at: roxanne.johnston@tucsonaz.gov
10/17/2025 PDSD Application Completeness Express REVIEW COMPLETED