Review Date Reviewer's Name Type of Review Description Status Comments
10/08/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/08/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT PDSD Residential Review Section PROJECT: TC-RES-1025-04902 Replace HVAC gas, split system and Replace gas water heater.-(1st Review) (2308 E 19TH ST) TRANSMITTAL DATE: October 8, 2025

Comments: 1) Please clarify if HVAC and water heater replacements are like-for-like or modifications. 2) If replacements are like-for-like, please update the floor plan to show where the HVAC system and water heater are located and resubmit with the Manual J. 3) If HVAC is a modified system, submit: floor plan showing location of equipment, HVAC template, electrical load calculations, electrical panel schedule with OCPD conductor size and type, gas pipe template and Manual J. 4) If water heater is a modified system, submit: floor plan showing location of water heater and electrical, electrical load calculations, electrical panel schedule with OCPD conductor size and type, gas pipe template.

Please email any questions to: PDSD-Residential@tucsonaz.gov
10/07/2025 PDSD Application Completeness Express REVIEW COMPLETED