Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADU v.1
Permit Number - TC-RES-1025-04869
Review Name: RESIDENTIAL ADU v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/16/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/07/2025 | Addressing Validation | REQUIRES RESUBMIT | ATTENTION: Parcel/addressing issue. The site plan shows to be for an ADU(Accessory Dwelling Unit). The location does not have units attached to the address and units do not appear to be associated with the parcel. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to verify and add the units. After address/units have been added or verified you'll need to submit an address change request through the permit sub records to update this record along with a new aerial/site plan that shows the corrected addressing. For questions: Building_Official@tucsonaz.gov |
||
| 10/16/2025 | Residential Building | REQUIRES RESUBMIT | TC-RES-1025-04869 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. Show the current code reference on the plans. The 2024 IRC will be in effect Jan 1, 2026. A permit requires the correct application type. Request the cancellation of this application for a new dwelling and apply for an addition/alteration permit. This is the correct permit type for addition living space on the property which does not include a cooking appliance such as a stove. The addition/alteration permit will become a great cost savings because a dwelling permit requires features not necessary for the space without the cooking appliance. The permit description should be Convert Shed into Sleeping Quarters. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. SITE PLAN: 1. Show the location and size of buildings, utility meters and gas, water, electrical, and sewer, R106.1.1. Show the location and size of lines with connection points, R106.1.1. Identify the utility lines requiring upgrade or replacement. PLANS: 1. Provide a hard surface landing or floor surface at the exterior door. A landing must be at least as wide as the door it serves and 36” in the direction of travel, R311.3. SECTIONS - DETAILS: 1. Provide a wall section detail showing the installation of R-13 insulation and ½” gypsum board, R106.1.1. 2. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. PLUMBING PLANS: 1. Show an appropriate yard pipe size and building shut off value in compliance with P2903.7. 2. Show the water heater rating, P2801.1. MECHANICAL PLANS: 1. Show the HVAC system size for the building demand in accordance with M1401.3, M1601.1. ELECTRICAL PLANS: 1. Designate the circuit number at the location of each light fixture, receptacle, appliance, and equipment disconnect switch, R106.1.1. 2. Show a smoke alarm with an electrical circuit, R314.3. 3. Provide a panel schedule showing the main ampacity consistent with the load summary, E3601.6.1 & E3706.2. 4. Verify the water heater circuit size for serving the load, E3702.11. A tankless water heater may require a larger circuit size. 5. Show a 2O AMP small appliance circuit at countertop receptacle outlets, E3703.2 and E3901.3. 6. Show a bathroom receptacle with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6. 7. Show a 20 AMP branch circuit in the laundry area; this circuit may not serve other locations, E3703.3 and 3901.8. 8. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans. OUTDOOR LIGHTING CODE 1. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 10/07/2025 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-RES-1025-04869 Location: 2210 E JUANITA ST Review Date: 10/7/2025 Site Engineering Comments: 1. Submission not sufficient, please provide a full site plan to show the location and setbacks for the proposed ADU. 2. Per the City of Tucson Inclusive Home Design Ordinance (https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf), all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards (https://www.access-board.gov/ada/chapter/ch04/). See TSM 7-01.4.3 for specifications, including slope and composition materials. 3. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 10/14/2025 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-FBB-0925-00126 756 S Longfellow Ave., Tucson, AZ 85711 Manufactured ADU (2nd Review) TRANSMITTAL DATE: 10/14/2025 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. The current plan does not include a site plan. Please visit https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example . While a site plan needs to be customized to the site, based on the example provided in the link, some examples of what the site zoning team need are provided below. Please add this information to your plot/site plan. a. The legal description (Catalina Vista Resub, Lot 2, Blk 6) b. A scale c. North arrow d. Owner name and address e. Lot dimensions f. Lot zoning and that of properties that touch the lot (R-1). g. Square footage of the primary residence. www.asr.pima.gov/ParcelData/Apex/12305/2990-1.JPG h. Lot coverage. This is the square footage of the residence (minus the porches), enclosed sheds, and the vehicular use area from measured from the edge of the driveway (interior to the lot) including areas used for movement, standing and parking (any garage or carport). i. Please show the distance from the back of the house to the proposed ADU. j. Please provide the distances from the ADU and the residence to the property lines. k. Draw, dimension, and label an accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards ( https://www.access-board.gov/ada/chapter/ch04/ ). See TSM 7-01.4.3 for specifications, including slope and composition materials. l. Provide the elevations for the ADU (North, South, East and West) and measure the height from design grade to the top of the wall. 2. Please show a dimension from the centerline of E Juanita St. to the edge of pavement or curb (approx.17’) and a dimension from edge of pavement or curb to the property line (approx. 8’) per Catalina Vista paving plans i-520_002: http://maps-and-records.tucsonaz.gov/construction-plans/details/I-520 3. The above are examples of information taken from the plot/site plan example and is not comprehensive. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 10/07/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |